AlARM COMMANDS

flTAlMP
Air filter alarm period
WPAlMP
Humidifier alarm period
DEHAlMP
Dehumidifier alarm period
SySAlMP
HVAC system alarm period
Permissions: Read/Write
Query
Syntax:
Command
Description: Requests the [alarm] alarm period setting .
Assignment
Syntax:
Command
Description: Sets the [alarm] alarm period to [value] .
Examples:
Response
Syntax:
Example:
Parameters
alarm: alarm command code
value: alarm period setting in months
FLT
WP, DEH, SYS
Default: OFF
SN[#] [alarm]ALMP?<CR>
SN[#] [alarm]ALMP=[value]<CR>
SN1 FLTALMP=OFF<CR>
SN1 SYSALMP=12<CR>
SN[#] [alarm]ALMP=[value]<CR>
SN1 FLTALMP=OFF<CR>
Node address 1 responds with an air filter alarm period setting of OFF .
COS: N/A
Range
[FLT, WP, DEH, SYS]
[OFF, 1, 3, 6, 12]
[OFF, 1 – 12]