Figure 17
Axcent Wiring Information
window example
Note
The connector strips, shown
as item 1 in Figure 18, are
arranged according to the pin
complement of the actual
AXCENT connectors. To
minimize wiring problems,
attempt to keep similar
functions within the same
plug.
16
Using AXCENTWire
1
6
7
8
9
13
14
4
5.
Click in the space at the top Gnd position (item 13 in Figure 17), between the
connector terminal and the function column to add a connect indicator. Item 5
in Figure 18 shows the indicator.
6.
Click to add all other connect indicators to the project file as required by the
equipment you want to control. If you click the connect indicator again, the
indicator is deleted from the project file.
7.
Use the vertical scroll bar icon and move the project file in the window so that
the top section of the relay connectors is visible.
8.
Hold down the Shift key and click in the space between relay 2A and the
function column. Then, hold down the Shift key and click in the space between
relay 3A and the function column.
9.
Hold down the Shift key and click at position 4A and 5A to add a common
jumper, and then at 6A and 11A to add a series of common jumpers. Item 6 in
Figure 18 shows the new common jumper. Hold down the Shift key and click
at the bottom of a jumper string to remove all or part of the common jumper.
10.
Use the vertical scroll bar icon and scroll back to the beginning of the project
file.
5
15
16
AXCENTWire System Wiring Documentation Program