Table A-1. Specifications, Option 002 (continued)
Voltage Range: +4.75V to 16V
Current Drain: 20mA maximum
Status Indicator output:
Open collector output:
Maximum Output Voltage (logic high) : + 16V
Logic Low output: + 0.4V maximum at 8mA
Remote Control (Trip, Reset, Inhibit) Control Isolator Bias Input.
Voltage Range: +4.75V to 16V
Remote Control Inputs (
Remote
Trip
,
Remote
Reset
)
Remote
Inhibit
On State (logic low):
Minimum forward current required (I
): 1.6mA Isolator forward voltage (V
) at 1.6 mA (I
): 1.4V typical, 1.75
f
f
f
maximum.
For Control Isolator Bias voltage greater than ± 5V, an optional resistor (Ropt) may be added to reduce drive current .
Off state ( logic high) maximum leakage current: 100 µ A.
REMOTE TRIP and REMOTE RESET Timing
Pulse duration (TL): 15 µ S minimum
Reset time (TH): 125 µ s minimum
Set-up time (Ts): 25 µ s minimum
OVP clear delay: 1 sec ± 30% Bias Supplies DC output Ratings:
Power-on Preset
Output Ratings: open collector output (referred to power supply common).
Maximum output voltage (logic high): + 16V
Logic low output: +0.4V maximum at 8mA
93