WI742C 08/00
NEW COMPAT#
not be removed for use on a system with a different compatibility number. Note: (1) If assigning compatibility numbers,
record and store them in a safe place. (2) The GEM-RP2ASe2 and GEM-RP3DGTL Keypads will function with or without
a Compatibility Number.
While the compatibility number may be changed, the old number must be known in order to program the new number.
Note: If neither the control panel nor the keypad is given a compatibility number, both default to "0000" (thereby
maintaining compatibility).
To program the compatibility number, press the
compatibility number that is programmed into the panel. Note: If the keypad had been previously programmed for a
compatibility number other than "0000", the display would read "OLD COMPAT# XXXX". Enter the existing number before
attempting to change it. Press the
EZM ADDRESS
designate the keypad as Group "01" at the "
number "01" through "06". (Each EZM must have a unique assigned group number, starting with "01" and proceeding
consecutively.) Press the
ZONE RESPONSE
3. At the keypad, enter the sum as a two-digit number "01" through "15" on the display, then press the
Example. Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter "14" at the keypad, then press the
Press the
button to continue or press the
A
Program Control Message
PROG CONTROL
MESSAGE#
Press the
button to continue (the display will loop back through selections,
A
for changes) or press the
01 OUT OF SYSTEM
(display will read "
(top two).
L
NAPCO Security Systems
Compatibility Number
The compatibility number is a 4-digit security code that, if programmed into
0000
both the control panel and each GEM-RP1CAe2 keypad, dedicates the
keypad to only that panel. That is, (a) similar keypads not having the correct
compatibility number will not operate in the system and (b) a keypad may
A
button to continue or press the
A
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
01
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Workbook) similar to its keypad address. If no other EZMs are to be used,
EZM ADDRESS 00
button to continue or press the
A
Zone Response
The normal loop response of each keypad expansion zone is 750mS,
however the response time of any zone can be reduced to 50mS as follows.
00
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
2. Add up the circled numbers.
J
button.
C
The Access-Control message normally displays "**ENTER NOW**" however
this display may be changed to any of the following messages:
1
button to exit the Keypad Configuration Mode
C
"). Then replace Jumper JP5 across Pins 1–2
button until "NEW COMPAT# 0000" is displayed. Enter the 4-digit
button to exit.
C
" display. In multiple-EZM systems, enter an assigned group
button to exit.
C
button to exit.
X
GEM-P9600 Installation Instructions
Page 19
J
button.
ENTRY
MESSAGE
0
"**ENTER NOW**" (Default)
1
"DOOR CONTROL"
"GATE CONTROL"
2
3
"LIGHT CONTROL"
"CONTROL #1"
4
5
"CONTROL #2"
6
"CONTROL #3"
!

Advertisement