1.5.1.11. INDICATION
This adjustment is normally unnecessary.
Used to set how to indicate the status information.
1.5.1.11.1. WARNING (for
This is to set the indication of a warning mark on screen to induce to replace the spare lamp after
auto-lamp changing or pre-announcement of the changing ("2.1.3.5 Warning indication", on page
80).
OFF: No indication.
MESSAGE, ☀: To display both pre-announcement of auto-lamp changing and a warning
mark to induce to replace the spare lamp.
☀: To display only the warning mark.
[Procedure]
1.
Select WARNING in INDICATION in MISC FUNCTION in the system menu.
Set OFF, MESSAGE ☀ or ☀.
2.
1.5.1.11.2. STANDBY
This is to set a blue LED indication on screen ("3.5 LED display", on page 91) at stand-by state.
LED: To light the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select STANDBY in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
1.5.1.11.3. ERROR
This is to set a blue LED indication on screen ("3.5 LED display", on page 91) at shutdown due to
errors.
LED: To blink the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select ERROR in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
1.5.1.11.4. BLOWOUT (for
This is to set a blue LED indication on screen ("3.5 LED display", on page 91) at lamp blowout
when BLOWOUT (chapter 1.5.1.13, on page 41) is set OPERATE.
LED: To blink the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select BLOWOUT in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
PH50, XL50, XL21 series Set-up and Installation Manual
C
h
a
n
g
e
r
)
C
h
a
n
g
e
r
X
X
L
L
2
2
1
1
or when the input board is selected in
40
P
P
H
H
5
5
0
0
and
X
X
L
L
5
5
0
0
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents