3 Functions
3.6.2

Digital output (DOUT)

Number:
Parameter range:
Function chart number:
Features:
- cycle time:
Binary states in the drive can be output via the digital output. As result of the fast
cycle time, it is possible to control external devices and to display the state in real
time. In order that higher powers can also be output, the internal signal (TTL level)
is amplified using a relay (refer to Fig. 3-23).
Relay:
- max. opening / closing time:
- voltage / current
BI: Fct. of DOUT 2
P0732.C
Fig. 3-23
The states, which are to be output, are defined using the "BI" parameter P0731
(digital output). For the definition, the "BO" parameter number or "CO/BO"
parameter number and the bit number of the particular state should be entered into
P0731. Frequently used states including the parameter number and bit are shown
in the following Table (refer to Table 3-11).
90
1
r0730 – P0748
FP2100
1 ms
Invert DOUTs
0 ... 7
P0748 (0)
0
(52:7)
-1
2
Digital output
5 / 10 ms
30 V DC / 5 A
250 V AC / 2 A
CO/BO: State DOUTs
r0747
.1
r0747
MICROMASTER 420
Issue 07/04
COM
Kl.11
NO
Kl.10
Operating Instructions
6SE6400-5AA00-0BP0

Hide quick links: