CCTO (Command Completion Time Out)
1
This bit shall be set to 1 if a Command Completion Time Out error has occurred.
SECTOR COUNT REGISTER FIELD DESCRIPTIONS
LBA Low/Mid/High
The address of the first uncorrectable error.
DEVICE REGISTER FIELD DESCRIPTIONS
DEV
This field indicates the selected device.
STATUS REGISTER FIELD DESCRIPTIONS
BSY
0
This bit shall be set to 0 indicating command completion.
DRDY
1
SE (Stream Error)
1
This bit shall be set to one if the data contained erroneous data (even though the correct amount of
data was transferred to the host). In this case, the LBA returned in the Sector Number registers shall
be the address of the first sector in error, and the Sector Count registers shall contain the number of
consecutive sectors that may contain errors.
DRQ
0
This bit shall be set to 0.
ERR
1
This bit shall be set to 1 if an Error register bit is set to 1.
44