RuggedBackbone™ RX1501
Installation Guide
Section 3.2.3
Chassis Ground Connection
The RX1501 chassis ground connection, shown in
screw. It is recommended to terminate the ground connection in a #10 ring lug. Torque on the chassis ground
connection should not exceed 30 in-lbs (3.4 Nm).
Figure 42: Chassis Ground Connection
Section 3.2.4
AC Power Supply Wiring Example
Figure 43: Wiring for Single AC Power Supply (HIP module shown)
NOTE
• For 125/230VAC rated equipment, a appropriately rated AC circuit breaker must be installed.
• It is recommended to provide a separate circuit breaker for each power supply module.
• Equipment must be installed according to applicable local wiring codes.
Chassis Ground Connection
Figure 42, "Chassis Ground
Connection", uses a #10-32
Chapter 3
Installation
19