Icemaker - Hoshizaki KML-250MWH Instruction Manual

Low-profile modular crescent cuber
Hide thumbs Also See for KML-250MWH:
Table of Contents

Advertisement

1. Icemaker

• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent is
required for the icemaker drain line.
Icemaker
Water Supply
Inlet
1/2" FPT
Bin
Icemaker
Drain Outlet
3/4" FPT
Fig. 4
Icemaker
Bin Drain Outlet
3/4" FPT
KML-250MAH
13
Icemaker Water Supply Line
Shut-Off Valve
Icemaker Water Supply Line
Drain Valve
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air gap
between the end of each pipe and
the drain.
2-inch (5-cm) air gap
Floor Drain