[b] AM-150BAF
APPROXIMATE
ICE PRODUCTION
PER 24 HR.
lbs./day (kg/day)
APPROXIMATE ELECTRIC
CONSUMPTION
Watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day (m
/day)
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG (kg/cm
G)
SUCTION PRESSURE
2
PSIG (kg/cm
G)
TOTAL HEAT OF REJECTION
Note: The data without *marks should be used for reference.
Ambient
Temp. (°F)
50
70
150 (68)
80
140 (64)
90
130 (59)
100
110 (51)
70
660
80
670
90
680
100
700
70
44 (0.17)
80
43 (0.16)
90
40 (0.15)
100
36 (0.14)
70
14
80
15.5
90
17
100
17.5
70
3.8
80
3
90
2.5
100
2
70
240 (1.65)
80
269 (1.85)
90
299 (2.06)
100
339 (2.33)
70
58 (0.40)
80
59 (0.41)
90
61 (0.42)
100
62 (0.43)
2460 BTU/h (AT 90°F /WT 70°F)
36
Water Temp. (°F)
70
140 (64)
130 (59)
130 (59)
120 (55)
120 (55)
110 (50)
105 (48)
100 (45)
670
690
690
710
710
720
750
46 (0.16)
43 (0.15)
43 (0.15)
36 (0.14)
36 (0.14)
34 (0.13)
34 (0.13)
30 (0.12)
15
16
17.5
18
18.5
19.5
19
20
3.8
3.8
3
3
2.5
2.5
2
2
243 (1.67)
244 (1.68)
270 (1.86)
273 (1.88)
301 (2.07)
303 (2.08)
340 (2.34)
342 (2.35)
58 (0.40)
58 (0.40)
59 (0.41)
59 (0.41)
61 (0.42)
61 (0.42)
62 (0.43)
62 (0.43)
90
730