4) Remove the 2 screws securing the top panel, then lift it off.
5) Remove all ice from the storage bin.
6) Remove the slope from the storage bin by carefully bending it in the center and
releasing it from the 2 slope shafts.
7) Remove the scoop. Remove the 2 thumbscrews securing the scoop holder, then remove
it.
8) Remove the screws securing the upper rear panel, then remove it.
9) Remove the clamp securing the drain plug, then lower the drain hose into a container.
See Fig. 14. Remove the drain plug to drain the water from the reservoir and evaporator
assembly.
10) After all of the water has drained, replace the drain plug in its correct position.
11) Remove the reservoir cover. Pour the cleaning solution into the reservoir until the
solution starts to flow through the overflow hose. Replace the reservoir cover in its
correct position.
Note: If there is excess scale on the extruding head, fill the reservoir as described
above, then use a clamp on the reservoir hose between the reservoir and
evaporator assembly to block flow. Remove the thumbscrews securing the spout,
then remove the spout. Pour additional cleaning solution over the extruding head
until the evaporator assembly is completely full.
12) Allow the icemaker to sit for 10 minutes before operation. If you placed a clamp on the
reservoir hose in step 11, remove it before operation and replace the spout in its correct
position.
13) Plug the unit back in. Move the power switch to the "ON" position.
14) Allow the unit to make ice using the solution. When ice stops coming out, move the
power switch to the "OFF" position. Unplug the unit from the electrical outlet.
15) Remove the drain plug to drain any remaining solution.
16) After all of the solution has drained, replace the drain plug in its correct position.
17) Remove the reservoir cover. Using a clean container, pour water into the reservoir until
it starts to flow through the overflow hose. Replace the reservoir cover in its correct
position.
18) Remove the drain plug to drain the water.
Note: If you do not sanitize the icemaker, go to step 11 in "Sanitizing Procedure - Final."
19) After all of the water has drained, replace the drain plug in its correct position.