Hoshizaki C-100BAF Service Manual page 34

Self-contained cubelet
Hide thumbs Also See for C-100BAF:
Table of Contents

Advertisement

7. Evaporator
8. Condenser
9. Refrigerant
10. Water System
1. Bin Control Thermostat Assembly
(with integrated heater)
NOTICE! Some units contain
a sticker that states: "The
bin control heater has been
disconnected. DO NOT
reconnect the bin control
heater." In this case, leave
the bin control heater
disconnected or replace
the bin control thermostat
assembly with 3A2561A03.
a) Dirty.
b) Damaged or defective.
a) Dirty.
a) Low charge or overcharged.
b) Refrigerant lines or components restricted.
a) Water leaks.
Shutdown
a) Out of position.
b) Out of adjustment. See "IV.C. Bin Control Check."
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C-100baf-dsC-100baf-adC-100baf-adds