Installer Setup - Honeywell FocusPRO Wi-Fi TH6000 Series Installation Manual

Wi-fi programmable
Hide thumbs Also See for FocusPRO Wi-Fi TH6000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Installer setup

Fan
1 Press
and
approximately 3 seconds. The screen will change
to display two numbers and the button designations
will be Done, Back, blank, Next.
Next
2 Press
until you see the function number—the
larger number on the left—you want to set.
3 Change options for any function by pressing
until the correct option (smaller number on right)
t
is displayed.
4 Repeat Steps 2 and 3 until you have set all
functions that you wish to change.
5 When you have made all changes, press
save and exit.
Function
1
Select System
Type
2
Heat Pump
Changeover Valve
(for heat pumps
only)
3
Heating Fan
Control
5
Heating Cycle
Rate
6
Heating Cycle
Rate Stage 2
7
Heating Cycle Rate
Auxiliary
9
1st stage compres-
sor cycle rate
10
2nd stage com-
pressor cycle rate
69-2738EFS—03
simultaneously and hold for
s
Settings & Options
0
Heat/cool: Gas, oil or electric heating with central air conditioning.
1
Heat pump: Heat pump without backup or auxiliary heat.
Heat only: Gas, oil or hot water heat without central air conditioning.
2
Heat only with fan: Gas, oil or electric heat without central air
3
conditioning.
4
Cool only: Central air conditioning only.
5
Heat pump: Heat pump with backup or auxiliary heating.
6
Heat/Cool Multiple stages: 2 heat stages, 2 cooling stages.
Heat/Cool Multiple stages: 2 heat stages, 1 cooling stage.
7
Heat/Cool Multiple stages: 1 heat stage, 2 cooling stages.
8
Heat Pump Multiple Stages: 2 heat stages, 2 cool stages.
9
Heat Pump Multiple Stages: 3 heat stages, 2 cool stages.
10
0
Cooling changeover valve: Use this setting if you connected a wire
labeled "O" to the O/B terminal.
Heating changeover valve: Use this setting if you connected a wire
1
labeled "B" to the O/B terminal.
0
Gas or oil heat: Use this setting if you have a gas or oil heating system
(system controls fan operation).
Electric heat: Use this setting if you have an electric heating system
1
(thermostat controls fan operation).
5
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
Electric furnace: Electric heating systems.
9
Hot water or high-efficiency furnace: Hot water system or gas furnace
3
(more than 90% efficiency).
Gas/oil steam or gravity system: Steam or gravity heat systems.
1
[Other options: 2,4,6,7,8,10,11,12]
3
Recommended for most compressors
[Other options: 1, 2, 4, 5 or 6 CPH]
or
s
Done
to
6
HOLD
MCR33893A
HOLD
MCR33884

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Focuspro wi-fi th6320wf

Table of Contents