Chapter 4 Setup
>
4.3 ETERNUS DX60/DX80 Setup
4.3.7

AC Automatic Linkage Mode Setup

When AC automatic linkage mode is enabled, the ETERNUS DX60/DX80 is automatically turned
on when the power supply recovers after a power failure. This section explains how to setup the
AC automatic linkage mode.
Procedure
1
2
3
P3AM-3042-03ENZ0
ETERNUS DX60/DX80 Disk storage system User Guide
Remove the front cover from the controller enclosure.
For details on how to remove the front cover, refer to
Front Cover" (page
58).
Turn the AUTO POWER switch of the controller enclosure to ON.
Push up the AUTO POWER switch to the "ON" side using the pin that is provided with the
ETERNUS DX60/DX80.
Pin
The AUTO POWER switch of the drive enclosure is set to "OFF"
IMPORTANT
as the factory setting, and should not be set to "ON".
If AC power is being supplied, turning the AUTO POWER switch
of the controller enclosure to the ON position will cause the
ETERNUS DX60/DX80 to turn on.
If the AUTO POWER switch of the controller enclosure is the ON
position, connecting the power cord to the outlet will cause the
ETERNUS DX60/DX80 to turn on.
Re-attach the front cover to the controller enclosure.
For details on how to attach the front cover, refer to
Front Cover" (page
58).
AUTO POWER
switch
"2.2.3 Attaching and Removing the
144
"2.2.3 Attaching and Removing the
End of procedure