3) The installation of IP-900E/IP-900D series in a rack should be such that
the amount of airflow required for safe operation of IP-900E/IP-900D
series is not compromised.
-
IP-900E/IP-900D series has ventilation opening at the right and
rear side.
-
Do not cover or close these ventilation openings to prevent
overheating.
4) The mounting of IP-900E/IP-900D series in a rack should be such that a
hazardous condition in not archived due to uneven mechanical loading.
To keep stability of the entire rack, please fix the rack to wall or floor
by suitable means.
-
Be careful about injury during installation of IP-900E/IP-900D
series into rack.
-
Do not install IP-900E/IP-900D series into your rack where
IP-900E/IP-900D series may make the entire rack unstable.
-
The weight of IP-900E/IP-900D series with the maximum
configuration: 2.3 kg
5) If IP-900E/IP-900D series is supplied from the power strip or the
service outlet of other units, it may overload the power supply cord of
the power strip or other units.
-
Confirm that the current rating of the power strip or the service
outlet exceeds the combined ratings of all equipment is supplying.
-
The electrical rating of IP-900E : Rated 100-240 VAC, 50/60 Hz, 1
phase, 0.38 - 0.20 A(IP-900E)/0.33 - 0.17 A(IP-900D) /0.35 - 0.18 A
(IP-900IID).
6) The reliable earthing of the rack-mounted equipment must be
maintained.
connections other than direct connections to the branch circuit (e.g., use
of the power strips or the power distribution unit).
Note: The high leakage current may flow through the power strip
earthing conductor if all power supply cords of IP-900E/IP-900D series
are connected to one power strip. The earth connection is essential
before connecting supply. If the power strip is not directly connected to
the branch circuit, the power strip which has the industrial type
attachment plug should be used.
7) For installing, IP-900E/IP-900D series shall be installed near the
wall-outlet and the wall-outlet shall be easily accessible.
2.1.3

Air flow into and out from the device

IP-900E/IP-900D series is forced air cooled. Be sure not to block the air intake/exhaust vents.
Provide an adequate amount of space around the vents.
The particular attention should be given to supply
21
Chapter 2 Installation and Connection
IP-900E/IP-900D series