For Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer found in the
manual bag. Plug the transformer leads to the green con-
trol module (see Figure 12). Then plug the transformer into
the side outlet on the junction box.
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
junction box included in the manual bag assembly. Maintain
correct polarity when wiring the junction box.
The junction box is installed by sliding one tab of the box
through the slot on the lower right side of the outer wrap
and driving a screw through the other tab into the pilot hole
on the outer wrap.
Operation using Battery Power
This fireplace has an optional battery operation. The sys-
tem is fully functional with the use of two "D" size batteries
without ordinary 110-120 VAC power.
TRANSFORMER OUTLET
PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
SEE NOTE 1
IGNITION
MODULE
(3V)
ON/OFF
WALL SWITCH
VALVE
GROUND
NEUTRAL
Figure 12. Intermittent Ignition (IPI) Wiring Diagram
u
FLAME SPARKER /
SENSOR
OPTIONAL
BATTERY
BACK-UP
ON/OFF
SWITCH
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts.
120 VAC is required at junction box unless equipped with battery back-up.
Wiring to the battery pack should be left disconnected in
order to conserve battery life. In the case of a loss of power,
simply connect red and black wire leads to activate battery
power (connect red to red, black to black). The fireplace
can be used as necessary. Once power (110 VAC) is re-
stored, disconnect red and black wire leads to extend bat-
tery life.
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Wall Switch
Position the switch in the desired position on a wall. Run a
maximum of 25 feet (7.8 m) or less of 16 A.W.G. minimum
wire and connect it to the fireplace ON/OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
120 VAC
TRANSFORMER
JUNCTION BOX
3V
REM
FAN
BROWN
17
SPARK TO
PILOT IGNITOR
IGNITION
MODULE
3V
ORANGE (IGNITOR)
WHITE (SENSOR)
BLACK
GROUND TO
FIREPLACE
CHASSIS
BLACK
OPTIONAL
BATTERY
BACK-UP
ORANGE
RED
BROWN
GREEN
HIGH TEMP
LIMIT SWITCH
PILOT ASSEMBLY
AND VALVE ASSEMBLY
MUST BE GROUNDED
(COMMON GROUND
WITH FIREPLACE
CHASSIS)