4. Rear Vent - Vertical Termination (DVP only)
One Elbow
Figure 7.14
Two Elbows
Figure 7.15
32
12 ft (3.66 m) min.
60 ft (18.29 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 26 ft (7.92 m)
Heatilator • Novus NDV Series • 4055-187 Rev. X • 6/13
0 min.
6 ft (1.83 m) max.
Note: Subtract 3 ft (914 mm) from the total horizontal
measurement for each 90° elbow installed horizontally.
Subtract 1-1/2 ft (457 mm) from the total horizontal
measurement for each 45° elbow installed horizontally.
0 min.
6 ft (1.83 m) max.