Performance Data Sheet
SmartWater Filtration System-GE ® MSWF Cartridge
This system has been tested and certified in filter model GE MSWF according
to NSF/ANSI Standards 42 and 53 for reduction
of the substances
listed below.
The concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible
limit for water
leaving the system, as specified in NSF/ANSI Standards 42 and 53.* (Safety factors built in for unmetered
usage.)
Standard
No. 42: Aesthetic
effects
Parameter
,
USEPA
MCL
Standard
No. 53: Health
effects
i
Parameter
USEPAMCL
1 NTU....
99.95% Reduction
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 rng/L
0.0002 rng/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
_n
n
0.005mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
l,fluent
Challenge
Effluent
% Reduction
Concentration
_
Average
Maximum
'
Average
Maximum
2.0 rng/L + 10%
0.06rng/L
0.i0 rng/L
97%
9.1%
at least 10,000particles/
408,333
670,000
95.5%
89.4%
mL
Influent Challenge '
Effluent
Concentration
11 ± 1 NTU ....
Minimum 50,000 L
0.15 mg/L± 10%
0.15 mg/L± 10%
0.006mg/L± 10%
0.006 rng/L ± 10%
0.002 rng/L ± 10%
0.009 mg/L ± 10%
0.210 mg/L ± 10%
0.015 mg/L± 10%
0.015 mg/L± 10%
0.080 mg/L ± 10%
0.225 mg/L ± 10%
107 to 10 Bfibers/L;
fibers > 10pm in length
Average
Maximum
0.38 NTU
0.5 NTU
< 1 #/L
4 #/L
< i ppb
< i ppb
3.1 ppb
9.0 ppb
0.34ppb
0.7 ppb
0.66 ppb
1.5 ppb
< 0.02ppb
<0.02 ppb
< 0.5 ppb
<0.05 ppb
7.7 ppb
35ppb
< i ppb
< i ppb
< 0.5 ppb
< 0.5 ppb
< i ppb
i ppb
< 0.5 ppb
< 0.5 ppb
<0.17 MF/L
< 0.17 MF/L
*Tested using pressure of 60 psig; pH of 7.5± 0.5; temp of 68o ± 5°F (20 ° ± 2.5°C).
**Measurement
in Particles/mL
Particles used were 0.5 i microns.
***Based on the use of Cryptosporidium
parvum oocysts.
....
NTU-Nephelometric
Turbidity Units
Ca parity 300 gallons (1,135 liters). Conta minant red uction determined by NSF testing.
Min: Required Reduction
->50%
->85%
% Reduction
'
MaX: Peimissible
Average
96.5%
>99.99%
99.3%
98.0%
94.0%
88.4%
>99.0%
>93.9%
96.0%
>92.9%
> 96.8%
> 98.7%
>99.7%
>99%
Maximum
95.4%
> 99.99%
99.3%
95.5%
89.6%
73.7%
>99.0%
>9¢3%
82.0%
>92.9%
> 97.0%
>98.7%
> 99.8%
> 99%
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 rng/L
0.0002 rng/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application
Guidelines/Water
Supply Parameters
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
Seeinsert for Warranty information.
Operating Specifications
• Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
• Temperature: 33-100°F (0.6-38°C)
• How rate: 0.9 gpm (3.14 Ipm)
General
Installation/Operation/Maintenance
Requirements
• Hush new cartridge at fuil flow for 4-1/2 gallons (about five minutes)to purge
trapped ain
• Replace cartridge when flow becomes too slow.
• Protect from freezing by removing filter cartridge
when temperatures
are
expected to drop below 40°F (4.4°C). Do not install systems in areas where
ambient temperatures
may go above 100°F or below 40°R Do not install
on a hot water supply.
Special
Notices
• Installation instructions are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologicaliy
unsafe or of unknown quality with-
out adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.
• Thecontaminants or other substancesremoved or reduced bythis water
treatment system are not necessarilyinyour water.
• Checkfor compliancewith the applicablestate and locallaws and regulations.
• Notethat whilethe testingwas performedunderstandard laboratory conditions,
actual performance may vary. Systemsmust be installedand operated in
accordance with manufacturer's recommended proceduresand guidelines.
• Installationand use MUST comply with all state and local plumbingcodes.Do not
install if water pressureexceeds120psi. Ifyour water pressureexceeds80 psi
(552kPa), y ou shouldinstall a pressure-limitingvalve.Contact a plumbing
professionalifyou are uncertain how to checkyour water pressure.
• Donot install where water hammer conditionsmay occur. Ifwater hammer
conditionsexistyou must installa water hammer arrester.Contact a plumbing
professionalifyou are uncertain how to check far this condition.
• Wherea backflow preventiondevice is installedon a water system,a devicefar
controlling pressuredue to thermal expansionmust be installed.
Forconditionsof use,health claims certified bythe CaliforniaDepartment of Public
Health,and replacements,see performance data sheet.CaliforniaDepartment
of PublicHealth Certification#06-1834.The contaminants or other substances
removed or reduced bythis water filter are not necessarilyinall users'water.
Tested and Certified
by NSF International
against ANSI/NSF Standards
42 and 53 in model GE MSWF for the reduction
of:
Standard
No. 42: Aesthetic
Effects
• Chemical
- Chlorine Taste and Odor
• Mechanical Filtration
- Particulate Reduction,Class I
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard
No. 53: Health Effects
• Chemical Reduction
- Atrazine Reduction
- Enddn Reduction
- Benzene and Carbofuran
Reduction
- 1,4 Dichlorobenzene
and
2,4-D Reduction
- Lead and Lindane Reduction
- Mercury and Toxaphene Reduction
• Mechanical Filtration
- Cyst and AsbestosReduction_
REPLACEMENT
ELEMENT
EPA#10350-MN-005
© 2010 General Electric Company
PC61577C
42

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile 23Profile 26Profile 29Profile 2725

Table of Contents