3.
Connect the air supply to the tool at the Air Plug (82-not included). Set the regu-
lator at the recommended 70 to 125 operating PSI. Do not exceed the maximum
125 PSI.
4.
Test the tool by depressing the Safety (38) against a piece of scrap wood without
pulling the Trigger (60). The tool must not cycle (fire). If it cycles (fires), stop im-
mediately and have it repaired by a qualified service technician.
(See Figure B.)
5.
Hold the tool away or off the workpiece. The Safety (38) of the tool should return
to its original position. Squeeze the Trigger (60). The tool should not cycle (fire).
If the tool cycles (fires), stop immediately and have it repaired by a qualified ser-
vice technician. (See Figure B.)
6.
Depress the Safety (38) against the workpiece and squeeze the Trigger (60). The
tool must cycle (fire) only once. Release the Trigger and squeeze it again. The
tool must not cycle (fire). With the Trigger held, carefully lift the Nailer and press it
against the scrap wood again. The tool must not cycle (fire). If it fails to perform
in the manner explained in bold, have it repaired by a qualified service technician.
(See Figure B.)
WARNING: Always wear ANSI approved impact safety goggles when re-
loading or performing any other maintenance on this tool. Other people in the
work area must also wear ANSI approved impact safety goggles.
WARNING! Make sure the Nailer is not attached to the air hose when
loading the tool.
1.
To open the Magazine Cover (91), press down on the Latch (57) and swing the
Door (32) open. Then, swing the Magazine Cover open. (See Figure C.)
LATCH
(57)
DOOR
(32)
SKU 93257
For technical questions, please call 1-800-444-3353
LOADING COIL NAILS
MAGAZINE COVER
(91)
FIGURE C
Rev 06k; REV 06l