Section 2: Framing - Montigo R324-ST Outdoor Installation & Maintenance Manual

See through residential fireplace
Hide thumbs Also See for R324-ST Outdoor:
Table of Contents

Advertisement

R324-STIO Indoor Outdoor Ventless Gas Fireplace

Section 2: Framing

Step 1. Frame the opening in the location that you have selected for
your fireplace. The dimensions of the opening should be X" wide by
Y" high. (see Table)
Unit must be 10" above grade
Figure 2: Framing Dimensions
Clearances:
R324-STIO
Figure 3:a Unit flush to interior wall
Page 6
Installation
X "
on exterior side
1/2"
0"
10"
3"
10" Min.
from grade
Figure 3b: Unit flush to exterior wall
Combustible Framing
Y"
Note: For all positions, outside face must be
positioned on OPEN non-obstructed patio.
10" Min.
from grade
Figure 3c: Unit extends beyond
both interior and exterior wall
X
Y
49"
48"
Building Wall
(Exterior)
Step 2. You may position the unit in framed
opening to be flush to the interior wall (Fig.
3a) flush to the exterior wall (Fig.3b), or
partially extending beyond both sides (Fig.
3c). Be sure to take into account finished
surfaces (exterior facade and interior
drywall or other finish when determining
final positioning.
Indoor
Outdoor
10" Min.
from grade
XG0775 - 032511