HighPoint CLI Reference
Rebuild Commands
You can use rebuild commands to rebuild a RAID1, RAID1/0 or RAID5
array when it is critical or broken.
Syntax
rebuild {array_id} {device_id}
rebuild {array_id} {start|stop}
rebuild {array_id} {device_id}
This command allows you to add the specified disk to a broken array and
rebuild it.
Example
HighPoint CLI> rebuild 1 1/3
This command instructs the controller to add the disk "
array "
". You can use the query commands first to verify the device ID and
1
the array ID information before the rebuild command.
Rebuild {array_id} {start|stop}
This command allows you to start or stop the rebuilding process on the
specified array. After you stopped a rebuilding process, you can resume it at
a later time by the rebuild start command.
Examples
HighPoint CLI> rebuild 1 start
This command starts the rebuilding process on the array "
HighPoint CLI> rebuild 1 stop
This command stops the rebuilding process on the array "
Verify Command
Syntax
verify {array_id} {start|stop}
This command starts or stops the verify process on the specified array.
Examples
HighPoint CLI> verify 1 start
" to rebuild the
1/3
".
1
".
1
- 11 -