MANUAL MODE

Moving the slide switch to the 'MANUAL' position selects the manual
operation mode of the RF receiver. In manual mode, the receiver
ignores the RF signal from the thermostat and controls the output relay
manually, based on the setting of the failsafe mode switch.

FAILSAFE MODES

Failsafe mode has three user selectable settings – 'ON', 'CYCLE' and
'OFF'. With the failsafe switch in the ON position, the output relay will
be turned on, in the OFF position the output relay will be turned off,
and in the CYCLE position the output relay will be operated according
to a preset time sequence (on for 4 minutes and off for 11 minutes).
When operating in failsafe mode, the LEDs will indicate the receiver
relay status as follows:
Mode
On
Off
Cycle
If required the user can switch to another mode without having to reset
the controller; for instance you can switch from auto mode to manual
mode with the output relay being controlled accordingly. To illustrate
this point, even when switched into manual mode the receiver can still
receive the RF signal from the thermostat and once the user switches to
auto mode, the output relay will be controlled to turn on or turn off
automatically once more.