Safety And Refrigerant Leak Check - Heat Controller VMH 09 Installation Manual

Version c inverterflex ductless mini-split
Hide thumbs Also See for VMH 09:
Table of Contents

Advertisement

Heat Controller, Inc.
Air Purging
AIR PURGING
Safety and Leak Check
Safety and leakage check
Electrical safety check
Perform the electric safe check after
completing installation:
1. Insulated resistance
The insulated resistance must be more than
2M .
2. Grounding work
After finishing grounding work, measure the
grounding resistance by visual detection and
grounding resistance tester. Make sure the
grounding resistance is less than 4 .
3. Electrical leakage check (performing during
test run).
test running)
During test operation after finishing installation,
the serviceman can use the electroprobe and
multimeter to perform the electrical leakage
check. Turn off the unit immediately if leakage
happens. Check and find out the solution
ways till the unit operate properly.
Refrigerant Leak Check
Gas leak check
1. Soap water method:
Apply a soap water or a liquid neutral
Apply a soap water or a liquid neutral
detergent on the indoor unit connection
detergent on the indoor unit connection
or outdoor unit connections by a soft
or outdoor unit connections with a soft
brush to check for leakage of the
brush to check for leakage of the
connecting points of th piping. If bubbles
connecting points of th piping. If bubbles
come out, the pipes have leakage.
come out, the pipes have leakage.
2. Leak detector
Use the leak detector to check for leakage.
CAUTION
A: Lo packed valve B: Hi packed valve
C and D are ends of indoor unit connection.
NOTE: The illustration is for explanation
NOTE: The illustration is for explanation
purposes only. The actual order of A, B, C
purpose only. The actual order of A, B, C
and D on the machine may be slightly
and D on the machine may be slightly
different from the unit you purchased. The
different from the unit you purchased. The
actual shape shall prevail.
actual shape shall prevail.
INSTALLATION MANUAL
Outdoor unit
check point
a,b,c,d,e,f,,h,i,j,k,m,n are points for one-three type.
Outdoor unit
check point
30
15
16
VMH InverterFlex Mini-Split
Indoor unit
check point
A
B
C
a,b,c,d,h,i,j , k are points for one-two type.
Fig.63
Indoor unit
check point
One-four type
Fig.64
j i h
n m k
f
e
d
c
b
a