Operation; Maintenance And Washing - White Rodgers SST1600 Owner's Manual

Sst series electronic air cleaner
Hide thumbs Also See for SST1600:
Table of Contents

Advertisement

OPERATION
1.
With the 120 VAC power turned on at the circuit
breaker for the fu mace, push the air cleaner ON-OFF
switch to the "ON" position (Figure 20).
2.
With thefurnace blower running, the aircleanerwill
be
operating. An arcing or "snapping" sound may be
heard. This will occur occasionally,
however the unit
is operating properly.
3.
With the furnace blower running, the Operating Light
should be ON. If the Operating Light is not ON this
signifies that the cells need washing, or that trouble
exists in the unit.
If, after washing the cells, the Operating Light stays off, the
cell could be wet, improperly placed in the cabinet or may
need servicing.
NOTE: An occasional flicker of the light accompanied by
harmless sparking or snapping noise may occur. This is
caused by trapping
large particles of dirt. If arcing is
continuous, the cells should be washed or checked for
service problems see Basic SST Service Guide.
L
J
O <
rTr]
._,,z_
-
-
Figure 20
__ Operating
Light
__ On-Off
Switch
MAINTENANCE
AND WASHING
CABINET
AND CELLS MAY CON-
TAIN SHARP EDGES.
Use care when servicing
unit or han-
dling cells.
Failure to do so could result in minor
personal injury.
For maximum efficiency your air cleaner cell(s) and pre-
filter(s) should be inspected once a month and cleaned
when necessary. Cleaning will usually be required every
one to three months, depending upon the particular house-
hold circumstances. When cleaning is required the follow-
ing procedure should be used:
CLEANING
THE CELLS
1.
Turn the air moving system "OFF."
2.
Push the ON-OFF switch on the power pack to the
"OFF" position (Figure 20). Wait 15 seconds and both
the power pack and the collecting
cell(s) will be
automatically discharged.
3.
Release the latch on top of power pack and pull the
power pack straight away from cabinet at the top.
Then lift pack out of ledge at bottom edge of cabinet.
Set power pack aside.
4.
Remove the cell(s) and pre-filter(s)
from cabinet.
Using a solution of warm water and low sudsing
detergent, soak cell(s) and pre-filter(s) for 20 to 30
minutes.
NOTE: Ionizing wires may become coated causing
loss of cleaning ability by the collecting cell. Using a
damp cloth, wipe each ionizing wire, exercising care
not to damage them.
5.
Remove the cell(s) and pre-filter(s) from solution and
rinse thoroughly with clean water.
6
Allow cell(s) and pre-filter(s) to drip dry for a minimum
of 2 hours. Cell(s) and pre-filter(s) may be tipped at
a slight angle to expedite the drip-dry process.
7.
Reinstall the cell(s) and pre-filter(s) in the cabinet.
8.
Replace the power pack. Turn fumace fan on. After 30
minutes push ON-OFF switch on the power pack to
the "ON" position.
A moderate amount of arcing or"snapping" may occur
at this time, which will indicate that the cell(s) are still
damp. If the noise is objectionable,
push the ON-OFF
switch to the "OFF" position and allow additional time
for cell(s) and pre-filter(s) to dry. In some cases the
Operating
Light will remain OFF during this initial
activation of the air cleaner, and this would indicate
that the cell(s) are not completely dry. The Operating
Light should remain ON while the furnace fan is
running once the drying is complete.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents