WIRING
INSTRUCTIONS
7.
With the cabinet installed, the air cleaner can now be
wired to electrical input source.
Installation
of this unit must comply
with local
electric
codes or other applicable
codes.
Review and understand
local codes prior to instal-
lation.
Failure to do so could result in serious
personal
injury or death.
10. If this unit has an electrical cord, the cord has a
grounding type plug with a third (grounding) pin. This
plug will fit only into a grounding type power outlet. If
the proper type of outlet is not available,
contact
qualified personnel to install a proper outlet. Do not
alter the plug in any way.
To reuce the risk of electric shock, The power cord
must be connected to an appropriate outlet. Do not
alter the plug in any way.
8.
An air cleaner unit with no air flow monitor requires
electrical wiring through the furnace controls. Con-
nect wiring to the furnace control terminals (EAC-H)
for power, (EAC-N) for neutral and connect metal
frame of EAC to ground.
If the air cleaner unit has an airflow monitor, it must be
connected to 120 VAC 60 Hz. A 20 amp circuit is more
than adequate. If an airflow monitor is not installed but
is required for operation, order Air Flow Kit F859-
0381. If a power cord is required, order F97-0019.
9.
Remove junction box cover and install the required
bushing into the 3/4 in. Knock out. With the supply
voltage turned off, route three (3) wires into junction
box for connections. (See Fig. 17.)
Insure all wires are clamped, wire connectors prop-
erly installed and grommets
used to prevent wire
abrasion.
Vertical
Section
\
Wood Block
7 Tape All
Joints
Hot
Neutral
Grounding
Conductor
Figure 16
r-== h
1
Front View
Figure 17
11. With the cabinet Installed, reinstall pre-filter(s) and
collecting cell(s) (Figure 18).
NOTE: The contact button and handles on the cell
must be facing you and ionizing wires must be on the
air intake side.
12. Install the power pack as follows:
Engage the lip on lower inside edge of power pack in
the flange on cabinet and carefully close the power
pack, making sure that the electrical connector prongs
on the power pack enter the slots in the socket on
cabinet. When the power pack isfully in place, engage
the latch and snap it closed.
Pre-Filters
Cabinet
Handle
Contact
Button
CollectingCells
Figure 18
Contact
Button
Power Pack
Female
Plug
Male
I_iPlug __
Side Edge
of
Power
Pack
Power
Pac_
_
z
Press to Close After_
[_ Latch
Latch is Engaged
/
j_.
_D
To Engage
_- Cabinet
/
Engage
Lip on Lower
Inside
Edge
of Power
Pack in Flange.
Figure 19 Installing Power Pack