Earth Tests (R
Limit Value
10
20
30
40
50
60
70
80
90
100

AC Voltage Measurement (V)

Range
Resolution
500 V
0.1 V
Continuity Testing (R
Range
Resolution
(Autoranging)
20
0.01
200
0.1
2000
1
Note
The number of possible continuity tests with a fresh set of batteries is 3000.
Range R LO
7.5 Ω
35 Ω
240 Ω
2000 Ω
Test Probe Zeroing
Live Circuit Detection
50
)
E
Maximum Display
Value
8.8
17.8
26.8
35.8
44.8
53.8
62.8
71.8
80.8
89.8
Accuracy
50 Hz – 60 Hz
0.8 % + 3
)
LO
Open Circuit Voltage
>4 V
>4 V
>4 V
Press the  to zero the test probe.
Can subtract up to 2
Error message for >2 .
Inhibits test if terminal voltage >10 V ac detected prior to
initiation of test.
Limit Value
200
300
400
500
600
700
800
900
1000
2000
Input Impedance
3.3 M
(1.5 % + 3 digits)
(1.5 % + 3 digits)
(1.5 % + 3 digits)
Test Current
210 mA
100 mA
20 mA
2 mA
of lead resistance.
Maximum Display
Value
179.8
268.0
358.0
448.0
538.0
628.0
718.0
808.0
898.0
1798.0
Overload Protection
660 V rms