Lcdi Power Cord And Plug - Soleus Air PH1-12R-03 Owner's Manual

Portable air conditioner, dehumidifier, heater and fan utilizing heat pump technology
Hide thumbs Also See for PH1-12R-03:
Table of Contents

Advertisement

LCDI POWER CORD AND PLUG
This air conditioner
is equipped
with an LCDI (Leakage
Current Detection
and Interruption)
power cord and
plug as required by US National
Electric Code 440.65. This cord consists
of a length of shielded flexible cord
with no termination
on the load side and a LCDI attachment
plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical
disconnect
(circuit trip) if the
nominal current leakage between
the cord shield and either load conductor
exceeds
a predetermined
value.
The cord will remain de-energized
until the devise has been manually
reset. This is intended
to reduce the
risk of a fire in the power cord or combustible
materials
nearby. The cord shields are not grounded
and they
must be considered
a shock hazards
if exposed. The cord shield must not be connected
to ground or to any
exposed metal.
The test and reset buttons
on the LCDI Plug are used to check if the plug is functioning
properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is pertbrmed
and the indicator
light remains
ON, current leakage
has been detected.
Do not use the
air conditioner
or attempt to reset the LCDI Plug. Contact
Soleus Air Customer
Service for troubleshooting
recommendations.
LCDI
TESTBUTTON
RESETBUTTON-_
TEST
_
POWE_
RESET
FRONT
BACK
|
|
J
WARNING:
1.
DO NOT press the TEST button while the air conditioner
is operating.
2.
The TEST and RESET buttons shouldnot
be usedas
"ON"
and
"OFF"
switches.
3.
The cord and plug are not intended to offer protection
to externally
connected
loads or supply
circuits.
4.
The cord and plug are intended
for indoor use only.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph1-14r-03Ph1-10r-03

Table of Contents