Soleus Air PH3-09R Operating Instructions Manual

Soleus Air PH3-09R Operating Instructions Manual

Portable air conditioner and heater with heat pump technology

Advertisement

Portable Air Conditioner and Heater
With Heat Pump Technology
PH3-09R-03 / PH3-10R-03
Operating Instructions
3046364
Model No. PH3-09R / PH3-10R
© 2006 Soleus Air International

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air PH3-09R

  • Page 1 Portable Air Conditioner and Heater With Heat Pump Technology PH3-09R-03 / PH3-10R-03 Operating Instructions 3046364 Model No. PH3-09R / PH3-10R © 2006 Soleus Air International...
  • Page 2: Important Instructions

    Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the opera- tional aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology.
  • Page 3: Package Contents

    These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. • If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly. MODEL Cooling Capacity...
  • Page 4: Product Diagram

    (Actual product design may differ slightly from images below) PRODUCT DIAGRAM FRONT A. Control panel B. Vertical air louvers C. Air outlet D. Horizontal air louvers E. Casters F. Power Cord & Plug BACK A. Hot air outlet grill B. Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters •...
  • Page 5: Installation

    If mounting in the wall, the height of the hole should be 16 to 50 inches (40cm to 130cm). Soleus Air does not provide a venting kit for through the wall ventilation. Venting through the wall requires a custom installation.
  • Page 6: Lcdi Power Cord And Plug

    3. Press RESET button for use If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
  • Page 7: Window Kit Installation

    WINDOW KIT INSTALLATION WINDOW KIT INSTALLATION The window kit is designed to fit into most standard vertical and horizontal windows, as well as some sliding glass doors. However, it may be necessary to modify some aspects of the installation process for certain window types.
  • Page 8 WINDOW KIT INSTALLATION (cont’d) NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images show general directions for all Soleus Air single hose portable air conditioners.
  • Page 9 CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL & MULTI-COLOR DISPLAY MULTI-COLOR DISPLAY A. Auto Mode B. Cool Mode C. Dehumidify Mode D. Fan Mode E. Heat Mode F. Fan Speed (Low, High, Me- dium) G. Temperature H. Swing Mode I.
  • Page 10 The timer will also remember the temperature settings, fan speed, and oscillation setting. The timer works when the unit is in Air Conditioner mode, Dehumidifier mode, Fan mode, and Auto mode. ”.
  • Page 11: Dehumidifier Mode

    OPERATING THE UNIT USING THE CONTROL PANEL Air Conditioner Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button on the control panel.
  • Page 12 3) When in SLEEP mode, the fan will run on low to keep fan noise at a minimum. 4) When in Air Conditioner mode, the temperature setting will gradually increase to 2 temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.
  • Page 13 Compressor Indicator The “ ” icon will light up on the control panel display when the compressor turns on. The “ turn off when the compressor shuts off. Emergency Condensate Holding Tank When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is used to cool the unit and make it run more efficiently.
  • Page 14: Operating The Unit Using The Remote Control

    3) Fan Speed - Press the FAN speed button to cycle through low, medium, and high fan speeds. 4) Temperature Setting - When the unit is in Air Conditioner mode you can select your desired tempera- ture. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the multi-color display on the control panel will increase or decrease accordingly.
  • Page 15: Maintenance

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
  • Page 16: Warranty

    WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air PH3-09R-03 / PH3-10R-03 Portable Air Conditioner with Heat Pump technology to be free of defects in material and workmanship for the applications specified in its op- eration instruction for a period of ONE (1) year from the date of original retail purchase in the United States.