Soleus Air PH1-12R-03 Owner's Manual

Soleus Air PH1-12R-03 Owner's Manual

Portable air conditioner, dehumidifier, heater and fan utilizing heat pump technology
Hide thumbs Also See for PH1-12R-03:

Advertisement

Portable Air Conditioner,
Dehumidifier, Heater and
Fan utilizing Heat Pump
Technology
OWNER'S
MANUAL
Model #: PH1-14R-03
(Reference#: KY-36)
PH 1-1 2R-03 (Reference#: KY-34)
3046364
Please read owner's manual carefully before operating
unit.

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air PH1-12R-03

  • Page 1 Portable Air Conditioner, Dehumidifier, Heater and Fan utilizing Heat Pump Technology OWNER'S MANUAL Model #: PH1-14R-03 (Reference#: KY-36) PH 1-1 2R-03 (Reference#: KY-34) 3046364 Please read owner's manual carefully before operating unit.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ................................IMPORTANT SAFEGUARDS ............................LCDI POWER CORD AND PLUG ..........................PRODUCT DIAGRAM ..............................INSTALLATION ................................CONTROL PANEL AND MULTI-COLOR DISPLAY ....................CONTROL PANEL FUNCTIONS ..........................OPERATION USING THE CONTROL PANEL ......................COOLING ..................................DEHUMIDIFYING ..............................FANNING ..................................HEATING ..................................
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the Soleus Air PH 1-14R-03/PH 1- 12R-03 Portable Air Conditioner and Heater utilizing heat pump technology. This unit is designed to improve indoor living and working comfort by providing cooling, dehumidi_ing, heating, and ventilation with minimal installation.
  • Page 4: Important Safeguards

    IMPORTANT SAFEGUARDS Before installing and using your portable air conditioner and heater, it is important that you read this owner's manual carefully. Store this manual in a sate place for future reference. This instruction manual is used for guidance and does not form part of a contract. It reserves the right to make technical...
  • Page 5: Lcdi Power Cord And Plug

    If a test is pertbrmed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations. LCDI TEST POWE_ TESTBUTTON RESET...
  • Page 6: Product Diagram

    PRODUCT DIAGRAM FRONT A. Control panel B. Vertical air louvers C. Air outlet D. Horizontalair louvers E. Casters F. Cable (powercord and plug) BACK A. Hot air outlet grill B. Lowerair inlet grill ACCESSORIES Drain tube Orain Flexible exhaust hosewith 2 adapters 3/8 '_sc_rew I pc •...
  • Page 7: Installation

    INSTALLATION SELECTING THE LOCATION Place the unit in a flat location where the air outlets are not obstructed.Place the unit at least 20" (50cm) away from a wall or other obstacle. MOUNTING THE EXHAI ST HOSE Slide the squareend of the exhaust duct over the hot air outlet on the back of the unit.
  • Page 8 WINDOW KIT INSTALLATION HORIZONTAL WINDOW The window kit is designedto fit into most standard vertical and horizontalwindows, as well as some slidingglass doors. However,it may be necessary to modify some aspects of the installationprocessfor certain window types. Open the window or slidingdoor and adjust the length of the window kit to fit the opening.
  • Page 9 |.sta||aUo. of the FOR SINGLE HOSE PORTABLE...
  • Page 10: Control Panel And Multi-Color Display

    CONTROL PANEL AND MULTI-COLOR DISPLAY CONTROLPANEL FAN SPEED Duringthe modes of cooling, heating and fanning, press this button to choose high, medium or low fan Button speed. In dehumidifyingmode, this button is inoperable. SWING Button Press this button to oscillate the vertical louvers or to stop oscillation. V Button This button decreasesthe room temperature/timerhours.
  • Page 11: Controlpanelfunctions

    CONTROLPANELFUNCTIONS -I 1 I M! l ON/OFF BUTTON Starts or stops the unit. MODE BUTTON @=_--K Press to select the operating mode: Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mode Auto Mode FAN BUTTON Press to select the fan speed: High, Medium, and Low.
  • Page 12: Operation Using The Control Panel

    OPERATION USING THE CONTROL PANEL COOLING Properly install the exhaust hoses. Plug the power cord into a grounded outlet. Turn on the unit by pressing the On/Offbutton on the control panel. Press the Mode button until icon appears on the multi-color display.
  • Page 13: Auto Mode

    AUTO MODE Properly install the exhaust hoses. Plug the power cord into a grounded outlet. Turn on the unit by pressing the On/Off button on the control panel. Press the Mode button until the "_" icon appears on the multi-color display.
  • Page 14: Remote Control & Operation

    REMOTE CONTROL & OPERATION The remote control provided with the unit can be used to operate the portable air conditioner. The remote control uses 2 AAA batteries (provided). Install the batteries before using the remote control. The remote control can be used to do all the operations that can be programmed from the control panel.
  • Page 15 WATER DRAINAGE When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is used to cool the unit and make it run more efficiently. When the unit is used in extremely humid environments, water will collect in a water container at the bottom of the unit.
  • Page 16: Maintenance

    MAINTENANCE Always turn off and unplugthe unit before cleaningto avoid electricalshock. CLEANINGTHE HOUSING Wipe the surface of the unit with a soft, damp cloth. Do not use abrasive chemicalsor detergents to cleanthe surfaceof the unit, as the unit may become scratched or damaged. Avoid direct exposure to sunlight as this may change the surface color.
  • Page 17: Troubleshooting

    TROUBLESHOOTING Before seeking repair or service, please check the following: PROBLEM POSSIBLE CAUSE REMEDY Is the unit plugged in? Securely plug the powercord into the wall outlet. Is the main powersupply on? Reestablishthe main powersupply. Unit does not operate or only runs in fan mode.
  • Page 18: Disclaimer

    TECHNICAL SPECIFICATIONS PHl-14R-03 PHl-12R-03 MODEL (Reference#: KY-36) (Reference#: KY-34) Cooling Capacity 14,000BTU/Hr 12,000BTU/Hr Heating Capacity 14,200BTU/Hr 12,200BTU/Hr DehumidifyingCapacity 65 pts/day 63 pts/day Cooling 1390 W 1340 W Power Consumption Heating 1180W 1090 W Air Flow Volume 328CFM 280CFM Power Source 115V / 60 HZ 115V / 60 HZ Cooling...
  • Page 19: Warranty

    WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air PHI-14R-03/PHI-12R-03 to be tree of detects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.