Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL _isted strain relief,
Disconnect
power before making e_ectdcal connections.
Connect neutral wire (white or center wire) to center
terminal
(silver),
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gotd).
Securely tighten
aimelectrical
connections,
Failure to do so can result in death, fire, or
e_ectrical shock,
1. Disconnect
power,
2. Remove the hold-down
screw and terminal block cover.
D
Fire Hazard
Use 10 gauge solid copper
wire,
Use a UL listed strain
relief,
Disconnect
power before making e_ectrica_ connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securety tighten
a_ e_ectrica{ connections.
Failure to do so can result in death, fire, or
electrical
shock.
3. Assemble a 3/4"(1.9 cm) UL listed strain relief (UL marking on
strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Put power supply cord through the strain
relief, The strain relief should have a tight fit with the dryer
cabinet and be in a horizontal position.
A. Neutral grounding
wire (green/yellow)
B. External ground conductor
screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
Now complete installation following instructions
for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)

Advertisement