Location Requirements - Whirlpool duet WFW9451XW00 Use & Care Manual

Front-loading automatic-washer
Table of Contents

Advertisement

Available languages

Available languages

Location Requirements
Selecting the proper location for your washer improves
performance
and minimizes noise and possible washer "walk."
Your washer can be installed under a custom counter, or in a
basement
laundry room, closet, or recessed area. See "Drain
System."
Companion appliance location requirements should also be
considered.
Proper installation is your responsibility.
You will need
A water heater set to deliver 120°F (49°C) water to the washer.
A grounded electrical outlet located within 6 ft (1.8 m) of
where the power cord is attached to the back of the washer.
See "Electrical Requirements."
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of
20-100 psi (137.9-689.6 kPa).
A level floor with a maximum slope of 1" (25 mm) under entire
washer. Installing the washer on soft floor surfaces, such as
carpets or surfaces with foam backing, is not recommended.
A sturdy and solid floor to support the washer with a total
weight (water and load) of 400 Ibs (180 kg).
Do not operate your washer in temperatures
below 32°F (0°C).
Some water can remain in the washer and can cause damage in
low temperatures.
Installation
clearances
The location must be large enough to allow the washer door to
be fully opened.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the washer is
recommended
to reduce noise transfer.
Companion appliance spacing should also be considered.
Washer Dimensions
521/2"
_(1335
38W'
{970 mrs)
Recommended spacing for custom undercounter installation
The dimensions
shown are for the recommended
spacing.
Custom
undercounter
installation
- Washer only
T-I' '1' 'll
(990mm)l
1"--_1_---27 ---_l_-- 1
{25tara) {686 ram) (25ram)
Recommended spacing for recessed or closet installation,
with or without a pedestal
The dimensions
shown are for the recommended
spacing.
Recessed
area or closet installation
--
y
(864mm) (310 cm 2)
w
(155cm 2)
1"--_,4 I_- 32"-_44"I_--
(25mm) (813 ram)(102 ram)
A. Side view - closet or confined area
B. Closet door with vents
*Min. top and bottom air openings for closet door.
Recessed
or closet installation
- Washer on pedestal
---
+
18"min.
(457ram)
Q
1"--)4 _-27"_1
_
l"-i_,q _- 32" --,,44"h_--
(25mm)
(686 ram)
(25mm)
(813 ram) (102 ram)
A. Recessed area
B. Side view - closet or confined area
(820ram)

Hide quick links:

Advertisement

Table of Contents
loading