iMPORTANT
SAFETY
INFORMATION
Safety markings are used to designate a degree or level
of seriousness
and should not be ignored. WARNING
indicates
a potentially
hazardous situation
that if not
avoided, could result in personal injuryor death. CAUTION
indicates
a potentially
hazardous situation
that if not
avoided, may result in minor or moderate injuryor property
damage.
OPERATING
INSTRUCTIONS
NOTE: Thermostat
styles vary. Some models may not
include the AUTO mode and others will have the AUTO
in place of the HEAT and COOL. Others may include all
three. Please refer to the thermostat manufacturer's User
manual for detailed programming instructions.
Cooling
Operation
1. Set the thermostat's system mode to COOL or AUTO
and change the fan mode to AUTO. See Figure 1.
2. Set the temperature selector to the desired temperature
level.The outdoor fan, compressor, and blower motorwill
all cycle on and off to maintain the indoor temperature
at the desired cooling level.
Heating Operation
(if optional heater kit is installed)
1. Set the thermostat's system mode to HEAT or AUTO
and change the fan mode to AUTO. See Figure 1.
2. Set the temperature selector to the desired temperature
level. The outdoor fan, blower motor, and heater kit will
cycle on and off to maintain the indoor temperature at
the desired heating level.
Turning the Air Conditioner
OFF
Change the thermostat's system mode to OFF and the fan
mode to AUTO (See Figure 1). NOTE: The system will not
operate, regardless of the temperature selector setting.
FAN
SYSTEM
TEMPERATURE
MODE
MODE
SELECTOR
Operating
the Indoor Blower Continuously
The continuous indoor blower operation is typically used to
circulate the indoor airto equalize a temperature unbalance
due to a sun load, cooking, or fireplace operation.
Set the thermostat fan mode to ON (Figure 1).The indoor
blower starts immediately, and will run continually until
the fan mode is reset to AUTO.
The continuous indoor blower operation can be obtained
with the thermostat
system mode set in any position,
including OFF.
AIR CONDITIONER
MAINTENANCE
Proper maintenance is most important to achieve the best
performance from the appliance and should be performed
frequently at the beginning of each air conditioning season.
zL WARNING:
Your
Air
Conditioner
contains
liquid
and
gaseous
refrigerant
under pressure,
installation
and
servicing
should
only
be attempted
by
qualified,
trained
personnel thoroughly
familiar
with
the
equipment
and
safe
responsible
refrigerant
handling
procedures.
Failure
to
comply
with
this
warning
could
result
in
equipment
damage,
personal
injury, or death.
Keep the unit clean. Hose off periodically and keep
unit fins clear of leaves and grass clippings.
Keep the unit clear of obstructions. DO NOT obstruct
airflow with tall plants or shrubs. DO NOT store gasoline
or other flammable materials on or near the unit.
Never operate the appliance without a filter installed in
the return air duct. Inspect filters frequently and replace
when necessary with filter of same dimensional size.
TROUBLESHOOTING
If the unit fails to operate, check the following:
• Check the thermostat setting. Make sure the system
mode and temperature settings are correct.
• Check the electrical panel for tripped circuit breakers.
• Check the filters for dust accumulation.
• Check the unit and make sure it is clean and not covered
with grass or leaves.
If the items above don't resolve your problems, then
call your nearest service technician.