Service Battery - Exmark Lazer Z XS Operator's Manual

Exmark zero turn riding mower operator's manual
Hide thumbs Also See for Lazer Z XS:
Table of Contents

Advertisement

3.3 SERVICE BATTERY

WARNING: Battery posts, terminals, and related accessories contain lead compounds, chemicals known
to the State of California to cause cancer and reproductive harm. Wash hands after handling.
The machine is shipped with a filled lead acid battery.
3.3.1
Unhook seat latch and tilt seat up to gain access to the battery.
POTENTIAL HAZARD
♦ Charging the battery may produce explosive gasses
WHAT CAN HAPPEN
♦ Battery gasses can explode causing serious injury.
HOW TO AVOID THE HAZARD
♦ Keep sparks, flames, or cigarettes away from battery.
♦ Ventilate when charging or using battery in an
enclosed space.
♦ Make sure venting path of battery is always open once
battery is filled with acid.
3.3.2
Check the voltage of the battery with a digital voltmeter. Locate the voltage reading
of the battery in the table below and charge the battery for the recommended time
interval to bring the charge up to a full charge of 12.6 volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected and the
battery charger used for charging the battery has an output of 16 volts and 7
amps or less to avoid damaging the battery (see the following chart for
recommended charger settings).
Voltage
Reading
12.6 or greater
12.4 – 12.6
12.2 – 12.4
12.0 – 12.2
11.7 – 12.0
11.7 or less
FIGURE 3
UPPER ROLL BAR INSTALLATION
DANGER
Percent
Charge
Charger Settings
100%
16 volts/7 amps
75 – 100%
16 volts/7 amps
50 – 75%
16 volts/7 amps
25 – 50%
14.4 volts/4 amps
0 – 25%
14.4 volts/4 amps
0%
14.4 volts/2 amps
- 15 -
Maximum
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links: