Lubrication Chart - Exmark Lazer HP Operator's Manual

Exmark zero turn riding mower operator's manual
Hide thumbs Also See for Lazer HP:
Table of Contents

Advertisement

NOTE: Do not add any type of tire liner or foam fill material to the tires.
Excessive loads created by foam filled tires may cause failures to the hydro drive
system, frame, and other components. Foam filling tires will void the warranty.
5.1.16
Check condition of belts:
a)
Stop engine, wait for all moving parts to stop, and remove key.
b)
Unhook seat latch and tilt seat up. Lift the rubber flap on front side of the
engine to check pump drive belt.
c)
Remove left and right belt shields on deck and lift up floor pan to inspect
deck drive belt.
d)
Check under machine to inspect the mule drive belt.
e)
See Sections 5.2.3, through 5.2.5 for belt adjustment.
5.1.17
Lubricate grease fittings:
a)
Stop engine, wait for all moving parts to stop, and remove key.
b)
Lubricate fittings with one to two pumps of NGLI grade #2 multi-purpose
gun grease.
Refer to the following chart for fitting locations and lubrication schedule.
LOCATIONS
1. Front Caster wheel hubs
2. Front Caster Pivots
3. Height Adj. Shaft Bearings
4. Deck Drive Belt Idler Arm
For Units With S/N 464,999 and Lower
For Units With S/N 465,000 and Higher
5. Brake Brackets
6. Mule Drive Belt Idler Arm
For Units With S/N 464,999 and Lower
For Units With S/N 465,000 and Higher
7. Pump Drive Belt Idler Arm
For Units With S/N 464,999 and Lower
For Units With S/N 465,000 and Higher
8. Deck Rear Struts
See Section 5.1.16 c) for special lubrication instructions on the front caster pivots and
Section 5.1.17 for special lubrication instructions on the front casters wheel hubs.
No. 6 (Mule Drive Belt Idler Arm)
Located Under Engine Frame
No. 7 (Pump Drive Belt Idler Arm)
Located Under Engine Frame
No. 4, 6, & 7 (Idler Pivots)
For Units with S/N 464,999 and Lower:
Monthly disassemble belt and spring and
grease under a "No Load" condition.
Service Interval: 40 hrs.
Service Interval: Refer to chart.

LUBRICATION CHART

FITTING
- 34 -
INITIAL
NO. of
PUMPS
PLACES
2
∗0
2
∗0
1
5
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
SERVICE
INTERVAL
∗yearly
∗yearly
40 hours
40 hours
Yearly
200 hours
40 hours
Yearly
40 hours
Yearly
40 hours

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lazer z

Table of Contents