Venting - Kenmore THE ECONOMIZER 153.333850 Owner's Manual

Gas water heater for use only in mobile homes
Table of Contents

Advertisement

To fillthe water heater with water:
I. Close the water heater drain v alve b yturning the handle tothe right
(clockwise).
The drain v alve i sonthe lower front ofthe water heater.
2. Openthecoldwatersupply valveto thewaterheater.
NOTE: The cold water
supply
valve must
be left open when
the water
heater
is in use,
3. To insure complete filling of the tank, allow air to exit by opening the
nearest hot water faucet. Allow water to run until a constant flow is
obtained.
This will let air out of the water heater and the piping.
4. Check all water piping and connections
for leaks. Repair as needed.
VENTING
Place the draft hood legs in the receiving holes on the top of the water
heater. The legs will snap in the holes to give a tight fit.
Place the vent pipe over the draft hood. With the vent pipe in position,
drill a small hole through
both the vent pipe and draft hood. Secure
them together with a sheet metal screw.
DRAFT HOOD INSTALLATION
DRAFT
HOOD
_
VE_.
VENT CAP
VE.T
TO
; COK
OUTDOORS
t
I
FIGURE
14,
temperature.
Such temperatures
may not be high enough to properly
open thermally
operated
vent dampers. This would cause spillage of
the flue gases and may cause carbon monoxide
poisoning.
Vent dampers
must bear evidence
of certification
as complying
with
the current edition
of the American
National Standard
ANSI Z21.68
(ANSI Z21.66 & 67, respectively,
cover electrically
and mechanically
actuated
vent dampers).
Before
installation
of any vent damper,
consult the local gas utility for further information.
To insure proper venting
of this gas-fired
water heater, the correct
vent pipe diameter
must be utilized.
Any additions
or deletions
of
other gas appliances
on a common
vent with this water heater may
adversely
affect the operation
of the water heater. Consult your gas
supplier
if any such changes
are planned.
Periodically
check the venting
system
for signs
of obstruction
or
deterioration
and replace if needed.
The combustion
and ventilation
air flow must not be obstructed.
The water heater with draft hood installed
must be connected
to a
roof jack, which terminates
to the outdoors.
Never operate the water
heater unless it is vented to the outdoors and has adequate
air supply
to avoid risks of improper
operation,
explosion
or asphyxiation.
Obstructed
or deteriorated
vent systems may present serious health
risk or asphyxiation.
The vent pipe from the water
heater
must
be no less than
the
diameter
of the draft hood outlet on the water heater.
All vent gases must be completely
vented
to the outdoors
of the
structure
(dwelling).
Install only the draft hood provided with the new
water heater and no other draft hood.
Vent pipes must be secured
at each joint with sheet metal screws.
There must be a minimum
of 6 inches (153 mm) clearance
between
single wall vent pipe and any combustible
material. For other than single
wall, follow vent pipe manufacturer's
clearance
specifications.
Failure
to have
required
clearances
between
vent
piping
and
combustible
material will result in a fire hazard.
Breathing
Hazard - Carbon
Monoxide
Gas
• Vent
dampers
must
be
certified
in accordance
with ANSI Z21.68.
• Vent
damper
must
permit
proper
drafting
of water heater.
• Install properlysizedventing.
• Do
not
install
without
venting
outdoors.
• Do notinstallwithoutdrafthood.
• Be alert for obstructed
or deterio-
rated
vent
system
to
avoid
serious
injury or death.
Breathing
carbon
monoxide
can cause brain damage
or
death.
Always
read and understand
instruction
manual.
VENT DAMPERS
-Any vent damper, whether it is operated thermally
or otherwise
must be removed
if its use inhibits
proper drafting
of
the water heater.
The water heater must be connected to a roof jack: The vent pipe from
the water heater to the roof jack must be no less than the diameter
of the draft hood outlet (min. 3" [76 mm]) on the water heater.
This water heater may be installed with single wall or Type B vent
pipe connection
to the draft hood and the following
U.L listed roof
jacks not furnished.
Van Dyke Ind. No. 987
Vent Line No. 2073
White Metal Products
3RJ
There must be a minimum
clearance
of 12" (305 mm) between
the
top of the draft hood and the top of the enclosure.
The draft hood and combustion
air inlet to the water heater must be
in the same atmospheric
pressure
zone. Do not separate
by a wall,
shelf, ceiling, partition,
or any other means.
There must be a minimum
of 6 inch clearance
between
single wall
vent pipe and any combustible
material.
Fill and seal any clearance
between
single wall vent pipe and combustible
material with mortar
mix, cement or other noncombustible
substance. For other than single
wall, follow vent pipe manufacturer's
clearance
specifications.
Thermally
Operated
Vent Dampers:
Gas-fired
water heaters
having
Be sure
vent pipe
is properly
connected
to prevent
escape
of
thermal efficiency in excess of 80% may produce a relatively low flue gas
dangerous
flue gases which could cause deadly
asphyxiation.
15