Problem
Engine is running, but noAC
output is available.
Cause
I.
Circuit breaker is open.
2.
Poor connection or defective cord
set,
3.
Connected device is bad.
Solution
I.
Reset circuit breaker.
2.
Check and repair.
4.
Fault in generator.
I.
Short circuit in a connected
load.
Engine runs good but bogs down
2.
Generator
is overloaded.
when
loads are connected.
3.
Shorted generator
circuit.
I.
Fuel valve is in the "Closed"
Engine will not start; or starts and
position.
runs rough.
2.
Low oil level.
Engine shuts down during
Out of gasoline.
operation.
Engine lacks power.
Load is too high.
See "Don't
Overload
Generator".
3.
Connect another device that is in
good condition.
4.
Contact Briggs and Stratton
service facility.
I.
Disconnect shorted electrical load.
2.
See "Don't Overload Generator".
3.
Contact Briggs and Stratton
service facility.
I.
Turn fuel valve to the "Open"
position.
2.
Fill crankcase to proper level.
Fill fuel tank.