Restoring Factory Defaults - Zoom B2.1u Operation Manual

Bass effects pedal
Table of Contents

Advertisement

Restoring Factory Defaults

To use this function, connect the [BALANCED
OUT] connector of the B2.1u to the PA mixer or
recording console, using XLR balanced cable. At
t h e s a m e t i m e , y o u c a n a l s o c o n n e c t t h e
[OUTPUT/PHONES] jack to the bass amplifier
for monitoring. (The amp settings will have no
effect on the signal supplied at the [BALANCED
OUT] connector.)
[BALANCED OUT]
connector
B2.1u
[OUTPUT/PHONES]
Bass guitar
jack
The [PRE/POST] switch lets you control the type
of signal supplied at the [BALANCED OUT]
c o n n e c t o r . T o u s e t h e s i g n a l a f t e r e f f e c t
processing, select the "POST" position (switch
engaged). To use the signal before effect
Restoring Factory Defaults
In the factory default condition, the patches of the user area (A0 – d9) contain the same settings as the
patches of the preset area (00 – 39). Even after overwriting the user patches, their original content can be
restored in a single operation ("All Initialize" function).
1.
Turn the B2.1u on while holding down
the [STORE] key.
The indication "AL" appears on the display.
2.
To carry out the All Initialize function,
press the [STORE] key once more.
24
Mixer
Bass amp
A L
processing, select the "PRE" position (switch
disengaged).
In certain configurations, a ground loop (electrical
signal loop created because devices within the
same system are connected to a separate ground)
may occur, leading to noise problems (audible
hum). In such a case, try setting the [GROUND]
switch to "LIFT". This may help to eliminate or
reduce the noise.
HINT
The [GROUND] switch determines whether the
[BALANCED OUT] connector is grounded or not.
When the switch is set to the "LIFT" position (switch
engaged), the ground pin of the [BALANCED OUT]
connector is uncoupled from the signal path. This can
be effective in eliminating or reducing hum noise
caused by a ground loop.
All patch settings are returned to the factory
default condition, and the unit switches to play
mode. To cancel All Initialize, press the
R
P
RHYTHM [
/
] key instead of the [STORE]
key.
NOTE
When you carry out All Initialize, any newly created
patches that were stored in the user area will be
deleted (overwritten). Perform this operation with care
to prevent losing any patches that you want to keep.