Salus ST620 Manual 140x140 Finish:Layout 1
DEFAULT PROGRAMMES
Programme
1
2
3
4
5
6
TEMPERATURE
Scale:
Tolerance:
Sampling Rate:
Display Range:
Display Resolution:
Set Temperature Range:
POWER SUPPLY
Power Source:
Battery Life:

MEMORY BACKUP

Type:
SWITCHING
Switching Voltage:
Switching Current:
Contact Type:
ENVIRONMENT
Operating Temperature:
Storage Temperature:
ST620 INSTRUCTION MANUAL
Output
Weekday
ON
6:00AM
TEMP
21ºC
ON
8:00AM
TEMP
14ºC
ON
11:00AM
TEMP
21ºC
ON
1:00PM
TEMP
14ºC
ON
4:00PM
TEMP
21ºC
ON
9:00PM
TEMP
14ºC
Celsius
Less than ± 0.5 ºC at 25 ºC
Every 15 seconds
0.0 ºC to + 45.0 ºC
0.5 ºC
5.0 ºC to + 35 ºC
2 x AA alkaline batteries (Don't use rechargeable batteries)
Approximately 1 year
Electrically Erasable Programmable Read Only Memory (EEPROM)
230V AC / 50Hz
10A resistive, 3A inductive
Volt Free
0 ºC to + 50 ºC
- 10 ºC to + 60 ºC
29/4/10
13:11
Weekend
6:00AM
21ºC
8:00AM
14ºC
11:00AM
21ºC
1:00PM
14ºC
4:00PM
21ºC
9:00PM
14ºC