3.11.2 HDD TEMP.

WARNING SETUP MENU
FAN FAULT
BUZZER
HDD TEMP.
ALARM OUTPUT
NO HDD
ALARM DURATION PERMANENT
HDD FULL
NETWORK ALARM NO
EMAIL
STOP RECORD
The enduring HDD temperature surveillance guarantees an alarm reaction in case the
threshold value is exceeded.
There may be several reasons for HDD temperature excess:
- Exceedance of the max. tolerable ambient temperature (40°C), e.g. upon installation in
an electrical cabinet with inadequate ventilation
- After-effect upon fan failure
- HDD defect
(1) BUZZER:
By selecting "ENABLE", the buzzer is activated upon HDD temperature excess.
(2) ALARM OUTPUT: Output relay activation.
1 – Output relay 1 ~ 4 (selection) switches upon alarm.
NONE – no output relay reaction upon alarm.
(3) ALARM DURATION: PERMANENT - This value cannot be changed, alarm is
automatically switched off after problem has been solved.
(4) NETWORK ALARM:
YES: Network alarm activated (for settings refer to NETWORK menu)
Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission
(5) EMAIL:
YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.
(6) STOP RECORD
YES: Recording process is stopped to avoid further temperature rise
and HDD damage.
NO: Recording process continues.