To Start The Engine
Disconnectall electrical loads from the generator. NEVER
start or stop engine with electrical devices plugged in and
turned ON. Follow start instruction steps in numerical order:
1.
Make sure unit is on a level surface.
IMPORTANT:Failureto start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2.
Turn red fuel valve to "On" position.
3.
Place choke lever in "Choke" position.
4.
Set On/Off switch to "On" position.
On/Off Switch is shown
_"'_._.
in On position
_y
5.
Grasp recoil handle and pull slowly until slight resistance
is felt. Then pull rapidly to start engine.
Starter cord kickback (rapid retraction) can result
in bodily injury. Kickback will pull hand and arm
_,,_
toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
o Whenstartingengine,pull cord slowlyuntil resistance is felt
andthen pull rapidlyto avoidkickback.
o NEVER startor stop enginewith electrical d evicespluggedin
andturnedon.
IMPORTANT:if engine floods, place choke lever in "Run"
position and crank until engine starts.
6.
Move choke lever to "Run" position a short distance at a
time over several seconds in warm weather or minutes
in cold weather. Let engine run smoothly before each
change. Operatewith choke in "Run" position.
NOTE:if engine starts after 3 pulls but fails to run, or if unit
shuts down during operation, make sure unit is on a level
surface and check for proper oil level in crankcase. This unit
may be equipped with a low oil protection device. If so, oil
must be at proper level for engine to start.
_
Contact with muffler
result in serious
area can
burns.
_
Exhaustheat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
o DONOT touch hot partsandAVOIDhot exhaustgases.
o Allowequipment t o coolbeforetouching.
o Keepat least5 feet (1.5m) of clearance on all sidesof
generatorincludingoverhead.
* Codeof Federal R egulation (CFR) T itle 36 Parks,Forests, a nd
PublicPropertyrequireequipment p oweredby an internal
combustion engineto havea sparkarrester,maintained in
effectiveworkingorder,complyingto USDA Forestservice
standard 5100-10or later revision.In the Stateof California a
sparkarresteris requiredundersection4442 of theCalifornia
Publicresources code.Otherstatesmay havesimilar laws.
Connecting EJectrical Loads
Let the engine stabilize and warm up for a few minutes
after starting.
DONOTconnect240Volt loadsto 120 Volt receptacles.
DO NOTconnect 3-phase loads to the generator.
DO NOTconnect 50 Hz loads to the generator.
Plug in and turn on the desired 120 Volt AC, single phase,
60 Hertz electrical loads.
DO NOT OVERLOAD THE GENERATOR. See "Don't
Overload Generator".
NOTICE
Exceeding generators wattage/amperagecapacity can
damage generator and/or electrical devices connected to it.
See"Don't Overload Generator".
Startgeneratorand letenginestabilizebeforeconnecting
electrical l oads.
Connectelectrical l oadsin OFF position,thenturn ONfor
operation.
Turnelectrical l oadsOFF and disconnect f rom generatorbefore
stoppinggenerator.
Stopping the Engine
1.
Turn off and unplug all electrical loads from unit. NEVER
start or stop engine with electrical devices plugged in
and turned on.
2.
Let engine run at no-load for two minutes to stabilize
unit's internal temperatures.
3.
Move On/Off switch to "Off" position.
4.
Move fuel valve to "Off" position.
WARNING
_
JBackfire, fire or engine damagecould occur.
N
DONOT stop engineby movingchokeleverto "Choke"
position.
11