"Setting up storage units for zSeries hosts running
prerequisite information that must be obtained to run FCP Linux on the zSeries.
1.
Choose one of the following methods to add devices: write a script or manually add the device.
To add more than one device to your SCSI configuration, write a small script that includes
all the parameters included. This is an optional step.
Alternatively, you can also add SCSI devices to an existing configuration with the add_map
command. After using this command, you must manually map the devices in the SCSI stack.
2.
To make the devices available permanently, after a reboot, you must create a new initial ramdisk
(RAM that is accessed like a disk) that contains the necessary modules and parameter information.
First, save the module parameters (see
on zSeries
Create a new ramdisk with the mk_initrd utility, then run the zipl utility to update the initial
program load record to point to the new ramdisk.
3.
Enable multipath support using the logical volume manager kernel for Linux z/FCP.
Create physical volumes using the following commands: pvcreate /dev/sda1 pvcreate
/dev/sdb1...
Put the physical volumes into a volume group using the following command: vgcreate
fcpvg /dev/sda1 /dev/sdb1...
Create as many logical volumes as you need using the following command: lvcreate --
size 16G fcpvg
Enable the alternate paths to the physical volumes using the pvpath command: pvpath -
-path0 --enable y /dev/sda1 pvpath --path1 --enable y /dev/sda1. If
both paths are set to a weight of 0, they will load balance.
4.
These configurations yield the SCSI device /dev/sda - /dev/sdc, This device is accessible
on the first path and the SCSI device /dev/sdd - /dev/sdf accessed on the second path.

FICON and ESCON migration overview

This section describes the process required to migrate a zSeries between FICON and ESCON adapters
and between a FICON bridge to a FICON adapter.
NOTE:
FICON support consists of hardware enhancements for enterprise servers, host software upgrades,
DS8000 LMC, and adapters. The FICON bridge performs the ESCON to FICON conversion.

Migrating from ESCON to native FICON

Native ESCON configuration

The following figure shows an example of a native ESCON configuration. The configuration shows
an S/390 or zSeries host that has four ESCON channels attached to the storage unit through two
ESCON directors.
hosts" on page 52) in the configuration file /etc/zfcp.conf.