Frequently,
aproblem tsminor
and a service call may not be necessary, use this troubleshooting guide for a
poss]bre so_ution. If the unit continues to operate Improperly, c arl Danby's Toll Free Number 1-800-263-2629 for
assistance, or call one ofour service depots listed in the enclosed "Authorized Service Depot"listingprovided
with thisunit,
Air conditionerwill
not operate°
Inefficient or no cooling.
Possible
Cause
No power to unlto
Dirty air filter.
Unit size Inappropriate
for application.
Blocked atr flow.
Power interruption, settings
changed too qutckty, or
compressor overload tripped.
Noisy unit.
Loose parts.
.......
Inadequate support.
Odors.
Formation of mold, mildew, or
Water dripping outside.
Water dripping Inside.
Ice or frost build-up.
algae on wet surfaces,
Hot and humid weather,
Unit is not properly angled to
allow water to drain outstdeo
Low outside temperature°
Unit air filter ls dirty,
NOTES:
Suggested
Solution
Check connection of power cord to
power source,
Check fuse or circuit breaker,
Clean or replace air filter.
Check with dealer to determine proper unit
capacity for application.
Remove obstruction from grill or
outdoorlouvers.
Turn the unit offand wait 5 minutes before
attempting to re-start.
Tighten loose parts.
Provide additional support to unit.
Clean unit thoroughly.
Place algaeclde tablet In base pan°
Condensation run-off ls normal under these
conditions,
Unit must be installed on an anglefor proper
condensation run-off., C heck theunitand
make any adjustments.
When outdoortemperature is approximately
65"F or below, frost may form when unit is In
cooling mode, Switch unit to FAN (only)
operation until frost melts.
Remove and clean fiitero
1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a
qualified technician.
2.. When unit is installed using proper installation steps, unit is properly hpped towards the outdoors
to aflow for condensation run-ofL