Danby DAC10560DE Use And Care Manual

Danby room air conditioner model dac9006de, dac10560de use and care manual
Hide thumbs Also See for DAC10560DE:

Advertisement

Quick Links

Room Air Conditioner
The model number of your room air conditioner is found on the serial
plate located on the right side of the unit above the power cord.
Model • Modèle
All repair parts are available for purchase or special order when you
visit your nearest service depot. To request service and/or the
location of the service depot nearest you, call the TOLL FREE
NUMBER: 1-800-263-2629
DAC9006DE
When requesting service or ordering parts, always provide the
following information:
DAC10560DE
• Product Type
• Model Number
• Part Number
• Part Description
For service, contact your nearest
Climatiseur de pièce
service depot or call:
Le numéro de modèle de votre climatiseur se trouve sur la plaque
d'information qui se trouve sur le coté droit de l'appareil par dessus le
cordon d'alimentation.
1-800-26-
Danby
(1-800-263-2629)
Toutes les pièces de rechange ou commandes spéciales sont
disponibles de votre centre régional de service autorisé. Pour exiger
le service et-ou le nom de votre centre de service régional, signalez le
Pour obtenir le service, consultez
NUMÉRO SANS FRAIS: 1-800-263-2629
votre succursale régionale de
Ayez les renseignements suivants à la portée de la main lors de la
service ou téléphonez:
commande de pièce ou service:
1-800-26-
Danby
• Genre de produit
(1-800-263-2629)
• Numéro de modèle
• Numéro de pièce
• Description de la pièce
Danby Products Limited, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio USA 45840
USE AND CARE
MANUAL
MANUEL
D'UTILISATION
Models • Modèles
DAC9006DE
DAC10560DE
Room Air Conditioner
Table of contents . . . . . . . . . . . . . . . . . . . . . . . 1
CAUTION:
Read and Follow All Safety Rules
and Operating Instructions Before
First Use of This Product.
Climatiseur de pièce
Table of contents . . . . . . . . . . . . . . . . . . . . . . . 14
PRÉCAUTION:
Veuillez lire attentivement
les consignes de sécurité et les
instructions d'utilisation avant
l'utilisation initiale de
ce produit.
Danby Products Limited, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio USA 45840
Version 1B.2.06

Advertisement

Table of Contents
loading

Summary of Contents for Danby DAC10560DE

  • Page 1 Room Air Conditioner The model number of your room air conditioner is found on the serial plate located on the right side of the unit above the power cord. Model • Modèle All repair parts are available for purchase or special order when you visit your nearest service depot.
  • Page 2: Table Of Contents

    En vertu de la présente, Danby Products Limitée (Canada) ou Danby Products Inc. (E.- U. d’A.) ne peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels, y compris à l’appareil, quelle qu’en soit les causes. Danby ne peut pas être tenue responsable des dommages indirects dus au fonctionnement défectueux de l’appareil.
  • Page 3: Introduction

    Thank you for choosing a Danby Designer Room Air Conditioner to cool your home. This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner.
  • Page 4: Electrical Specifications

    BEFORE installing and Rated Volts operating this unit. Amps 3. This 115V air conditioner uses 8.4 or less (depending on model) nameplate amps and may Wall Outlet be used in any properly wired, general purpose household receptacle. See Table 1 for Fuse Size specifications for individual branch circuit.
  • Page 5 Remove from carton, the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1 Energy-Saving Tips 4.
  • Page 6: Installation

    Installation Select the Best Location A. This room air conditioner is designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.
  • Page 7 • Extend the shutter from the shutter frame and slide it into the shutter guide on the side channel of the air conditioner as shown in Fig. 4. • Slide the shutters into the top (“L” Shaped) and Canal supérieur bottom (“U”...
  • Page 8: Keypad Features

    3. Select the appropriate mode under which you want CHECK FILTER : The adjacent indicator light will the unit to operate (Auto-Cool-Dry-Fan Only) illuminate as a reminder to clean the air conditioner 4. Select the fan speed setting. filter (see page 9) Once the filter has been 5.
  • Page 9: Remote Control Features

    Conseils d'économie d'énergie 3. Utilisez des draperies, rideaux ou stores pour empêcher les rayons du soleil directs de réchauffer la pièce, mais n'obstruez PAS le climatiseur. Permettez Votre climatiseur de chambre a été conçu pour être à l'air de circuler autour de l'appareil, sans obstacle. d'une grande efficacité...
  • Page 10: Care And Maintenance

    1. DO NOT use gasoline, benzine, thinner or other 3. Clean filter. chemicals on the air conditioner as these 4. Store (covered) air conditioner in a dry location. substances may cause damage to the paint finish and deformation of plastic parts.
  • Page 11: Trouble Shooting Guide

    Introduction Nous vous remercions d'avoir choisi un climatiseur de chambre Danby Designer pour refroidir votre logement. Ce manuel d'utilisation et d'entretien fournit les renseignements nécessaires pour prendre soin et entretenir votre nouveau climatiseur de chambre. S'il est adéquatement entretenu, votre climatiseur vous donnera de nombreuses années d'utilisation sans problème.
  • Page 12: Warranty

    This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby, and is non-transferable. TERMS OF WARRANTY Plastic parts such as handles and knobs, are warranted for thirty (30) days only from purchase date, with no extensions provided.

This manual is also suitable for:

Dac9006de

Table of Contents