CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #770-969
FOR P95-2 USING SIT 820 NOVA GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit Contains:
Qty. Part #
Description
1
910-018
SIT Conversion Kit-50%
Turndown LP
1
910-037
LP Injector (Pilot Orifice)
1
904-431
Burner Orifice #49
1
908-255
Decal "Converted to Propane"
1
908-529
5/32" Allen Key
1
918-117
Instruction Sheet
1) Turn the gas off.
2) Remove the glass frame.
3) Remove the logs, embers, and brick panels
(if used).
4) Remove the burner/grate assembly, first by
removing the two screws, one on each
side of the grate, then pull out the grate.
Remove screw
Pull out the
grate.
5) Remove the 2 screws, one on each side of
the burner. Slide the burner to the left and
then lift out.
Remove screw
Slide the
burner to the
left and lift out.
Excalibur P95-2 Zero Clearance Direct Vent Gas Fireplace
6) Pull off the pilot cap to expose the pilot
orifice.
7) Unscrew the pilot orifice with the allen key
and replace with the LP pilot orifice in the kit
and replace pilot cap.
Allen Key
8) Remove burner orifice with a 1/2" wrench
and discard. Use another wrench to hold
on to the elbow behind the orifice.
Burner
Orifice
9) Reinstall new burner orifice LP stamped #48
and tighten.
10) Remove and discard the 3 pressure regu-
lator mounting screws (A), pressure regu-
lator tower (B) and diagram (C).
11) Insure that the rubber gasket (D) is properly
positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.
12) Reverse steps 6) to 1).
INSTALLATION
13) Attach clear label "This unit has been con-
verted to Propane" near or on the serial #
decal. Attach white label "This valve has
been converted from NG to LPG using SIT
conversion Kit Code 0.907.204" onto the
valve.
14) Replace yellow "Natural Gas" label with red
"Propane" label
15) Check for gas leaks.
16) Check inlet and outlet pressures.
17) Check operation of flame control.
18) Check for proper flame appearance and
glow on logs.