HP StorageWorks 8000 - NAS Overview page 38

Hp surestore nas 8000 high availability solution integration manual
Hide thumbs Also See for StorageWorks 8000 - NAS:
Table of Contents

Advertisement

38
Installation Guide
4.
Connect the components to the Power Distribution Unit (PDU):
a
Connect the power cables of the components in each rack to the PDU strip on the rack as
shown in the diagrams in "Solution Integration and Product Configuration Overview" on
page 3.
Note
Each NAS server must be connected to a separate UPS.
b
Plug the PDU into the Power Distribution Panel (PDP) on the UPS.
c
Power up the components one at a time, in the following sequence, to minimize current
inrush:
1. UPS systems
2. Tape library
3. FC switches
4. Disk enclosures
5. Storage arrays
Do not boot the servers until the storage array has finished powering up. As the
Caution
array is powering up, amber and green lights will turn on and blink. When only
green lights remain on, it is safe to boot the NAS server.
6. Quorum server
7. NAS servers

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 8000

Table of Contents