Craftsman 315.212380 Operator's Manual page 21

10 in. compound miter saw with laser double insulated
Table of Contents

Advertisement

PHiLLiPS
SCREW
N
LOWER
BLADE GUARD
BLADE
BOLTCOVER
BLADE
TO
LOOSEN
FLAT(S)
ONSPINDLE
BLADE
TIGHTEN
BOLT
OUTERBLADEWASHER
WiTH DOUBLE "D" FLATS
iNNERBLADE
WASHERWiTH
DOUBLE "D" FLATS
Fig. 21
[] Remove the laser guide or outer blade washer. Do not
remove inner blade washer.
[] Wipe a drop of oil onto inner blade washer and outer
blade washer where they contact the blade.
SPINDLE
LOCKBUTTON
Fig. 22
,_
WARNING:
If inner blade washer has been
removed, replace it before placing blade on
spindle. Failure to do so could cause an accident
since blade will not tighten properly.
[] Fit saw blade inside lower blade guard and onto
spindle. The blade teeth point downward at the front
of saw as shown in figure 21.
_lb,
CAUTION:
Always install the blade with the blade
teeth and the arrow printed on the side of the blade
pointing down at the front of the saw. The direction
of blade rotation is also stamped with an arrow on
the upper blade guard.
[] Replace the laser guide or outer blade washer (see
instructions on the following page). The double "D"
flats align with the flats on the spindle.
[] Depress spindle lock button and replace blade bolt.
NOTE: The blade bolt has left hand threads. Turn blade
bolt counterclockwise
to tighten.
[] Tighten blade bolt securely.
[] Replace the lower blade guard and blade bolt cover.
[] Retighten the phillips screw securing the blade bolt
cover.
CAUTION:
Make sure the spindle lock button is not
engaged before reconnecting
saw to power source.
Never engage spindle lock button when blade is
rotating.
21