Location - Electric Steamers & Steam Generators; Electrical Connection - Vulcan-Hart VHX24 Series Installation & Operation Manual

Vhx24, vhl2, vhl3 & vh3616 series food steamers & mhb24 series steam generators
Hide thumbs Also See for VHX24 Series:
Table of Contents

Advertisement

LOCATION — ELECTRIC STEAMERS & STEAM GENERATORS
Position the steamer or steam generator in its final location.
The recommended clearance for proper operation is 36" (
from combustible or non-combustible construction is 0" at the sides and back. The recommended
clearance for service access is 18" (
require removal of adjacent equipment during servicing at customer's expense.
An exhaust system should be located directly above the steamer to exhaust steam and heat generated
by the steamer.
IMPORTANT: Do not locate the boiler base directly over a drain.
ELECTRICAL CONNECTIONS — ELECTRIC STEAMERS & STEAM GENERATORS
WARNING:
ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
Connect the electrical supply circuit to the terminal block in the field connection box located behind the
left side panel at the rear. A 1
on the side of the control box. Use copper wire suitable for at least 75 C. A grounding wire must be
connected to the ground lug.
The wiring diagram is located on the door of the boiler.
Volts
Hertz
Phase
208
60
208
60
240
60
240
60
480
60
Compiled in accordance with the National Electrical Code, ANSI-NFPA-70 (latest edition).
45.7 cm
7
/
" (
) diameter hole for 1
4.8 cm
8
ELECTRICAL DATA
Total KW
1
24
24
3
36
42
1
24
24
3
36
48
24
3
36
48
) at the front. The required clearance
91.4 cm
) at the sides and back. Clearances less than 18" may
1
/
" (
3.8 cm
2
Machine Amps
115.4
66.6
99.9
116.6
100
57.7
86.6
115.5
28.9
43.3
57.7
– 9 –
) trade-size conduit is provided
Minimum Circuit Ampacity
Maximum Protective Device
AMPS
150
90
125
150
125
90
125
150
50
70
90