Tx Gain Alignment; Rev Alc Alignment; Swr Alignment - Vertex Standard VX-1700 Series Service Manual

Hf multi mode mobile radio exp version
Hide thumbs Also See for VX-1700 Series:
Table of Contents

Advertisement

TX G
A
Connect the 50 Ohm Dummy Load and Inline
Wattmeter to the ANT jack.
Connect the AF Generator to pin 4 of the MIC
jack, and adjust the AF Generator output level
to 0.5 mV @1 kHz.
Referring to the Table below, press the [ ALARM ] /
[ 2128 ] key to recall each parameter listed, then
key the transmitter (connect pin 3 of the MIC jack
to GND) and rotate the CH knob for the required
output.
Parameter
Output Power
1TX-G-H
50 W (± 10 W)
2TX-G-H
63 W (± 10 W)
3TX-G-H
50 W (± 10 W)
4TX-G-H
50 W (± 10 W)
5TX-G-H
50 W (± 10 W)
6TX-G-H
50 W (± 10 W)
7TX-G-H
50 W (± 10 W)
MIC J
Parameter
Output Power
1TX-G-L
5 W (± 1 W)
2TX-G-L
5 W (± 1 W)
3TX-G-L
5 W (± 1 W)
4TX-G-L
5 W (± 1 W)
5TX-G-L
5 W (± 1 W)
6TX-G-L
5 W (± 1 W)
7TX-G-L
5 W (± 1 W)
P
REV ALC A
Connect the 150 Ohm Dummy Load (or three 50
Ohm Dummy Loads in parallel) to the ANT jack.
Referring to the Table below, press the [ ALARM ] /
[ 2128 ] key to recall each parameter listed, then
key the transmitter (connect pin 3 of the MIC jack
to GND) and rotate the CH knob just to the point
when the S-meter reading is changed from S-7
to S-8.
Parameter
1R-ALC
2R-ALC
3R-ALC
SWR A
Connect the 150 Ohm Dummy Load (or three 50
Ohm Dummy Loads in parallel) to the ANT jack.
Press the [ ALARM ] / [ 2128 ] key to recall the pa-
rameter "1_SWR3."
Key the transmitter (connect pin 3 of the MIC
jack to GND), then press the [ ENT ] key.
Press the [ 2128 ] key momentarily to recall the
parameter "2_SWR3."
Key the transmitter (connect pin 3 of the MIC
jack to GND), then press the [ ENT ] key.
Press the [ 2128 ] key momentarily to recall the
parameter "3_SWR3."
Key the transmitter (connect pin 3 of the MIC
jack to GND), then press the [ ENT ] key.
This completes the internal alignment routine.
To save all settings and exit, press and hold in the
[ ENT ] key for at least one second.
To exit without saving, press the POWER key.
Alignment
S-meter reading
S-7 to S-8 threshold.
S-7 to S-8 threshold.
S-7 to S-8 threshold.
17