Software Menu Alignment; Tx Output Power Alignment - Vertex Standard VX-1700 Series Service Manual

Hf multi mode mobile radio exp version
Hide thumbs Also See for VX-1700 Series:
Table of Contents

Advertisement

Alignment

Software Menu Alignment

The ANT jack should be connected to a Dummy
Load (in the case of transmission) or RF Signal Gen-
erator (in the case of reception). General alignment
conditions are as follows, unless otherwise noted.
VOL Knob: Center (12 o'clock position).
SQL Knob: Fully counter-clockwise.
TX Output Power: HIGH
VOX:Off
The channel data in the radio is preset per the chart
below.
Channel
1-001
1-002
1-003
1-004
1-005
1-006
1-007
Press and hold in the keypad's [ 1 ( MODE )] ,
[ 4 ( STEP )] , [ 7 ( V/M )] , and [ F ] keys simultaneously,
and turn on the radio while holding them in; the
alignment menu will then be activated.
In the alignment procedures, each alignment param-
eter is selected by pressing the [ ALARM ] / [ 2128 ] key.
Each alignment item is selected by rotating the CH
Knob. To
the alignment parameters when you
are satisfied with the adjustment, press the [ F ] key
for
than a half second.
Note that a few alignment parameters are not ad-
justable, and are to be left as set at the factory.
16
Frequency
1.7000 MHz
3.5000 MHz
5.5000 MHz
7.5000 MHz
12.0000 MHz
19.8000 MHz
29.0000 MHz
TX O
P
A
Connect the 50 Ohm Dummy Load and Inline
Wattmeter to the ANT jack.
Referring to the Table below, press the [ ALARM ] /
[ 2128 ] key to recall each parameter listed, then
key the transmitter (connect pin 3 of the MIC jack
to GND) and rotate the CH knob for the required
output.
Parameter
Output Power
1PO-VH
125 W (± 5 W)
1PO-H
100 W (± 5 W)
1PO-MH
50 W (± 5 W)
1PO-ML
25 W (± 1 W)
1PO-L
10 W (± 1 W)
2PO-VH
125 W (± 5 W)
2PO-H
100 W (± 5 W)
2PO-MH
50 W (± 5 W)
2PO-ML
25 W (± 1 W)
2PO-L
10 W (± 1 W)
3PO-H
100 W (± 5 W)
3PO-MH
50 W (± 5 W)
3PO-ML
25 W (± 1 W)
3PO-L
10 W (± 1 W)
4PO-H
100 W (± 5 W)
4PO-MH
50 W (± 5 W)
4PO-ML
25 W (± 1 W)
4PO-L
10 W (± 1 W)
Parameter
Output Power
5PO-H
100 W (± 5 W)
5PO-MH
50 W (± 5 W)
5PO-ML
25 W (± 1 W)
5PO-L
10 W (± 1 W)
6PO-H
100 W (± 5 W)
6PO-MH
50 W (± 5 W)
6PO-ML
25 W (± 1 W)
6PO-L
10 W (± 1 W)
7PO-H
100 W (± 5 W)
7PO-MH
50 W (± 5 W)
7PO-ML
25 W (± 1 W)
7PO-L
10 W (± 1 W)