(6) SI (Shift In)
When the SI code is input, all data that follows it will be printed out in con-
densed characters. This code is cancelled by the input of "DC 2" code. The
SI code can be input at any column position on a line, but all characters/
symbols on the line containing SI code are printed out in condensed
characters.
When printing condensed characters, the data capacity of the print buffer
will become 132 columns per line.
When the SO code is received after the input of the SI code, condensed
enlarged characters (double width of condensed characters) can be
printed. This condition is cancelled by "DC 4" code, and the character size
returns to "condensed."
(7) DC 4 (Device Control 4)
The DC 4 code cancels the SO mode.
DC 2
(8)
(Device Control 2)
The DC 2 code cancels the SI mode.
HT
(9)
(Horizontal Tab)
The HT code carries out the horizontal tabulation.
If there is no tab position set, this code is ignored. The tab stop positions
are set by "ESC D+n" (described later).